                      NetApp E-Series and EF-Series             
                      =============================             
                
==================================================================================         
      SANtricity(R) OS, NVSRAM and ESM firmware archive README              
                          Version 08.20.20.00
                             September 2016
==================================================================================         
                
Contents:               
=========                       
1. Overview             
   1.1 Archive Description              
   1.2 Package Contents         
   1.3 Component Version Formatting
   1.4 Software Dependencies
   1.5 Installation
2. Resolved Issues              
3. Revision History   
4. Trademark Information
                
1. Overview             
===========             
This document provides information on the E-Series and EF-Series SANtricity OS (Controller Firmware), Controller NVSRAM, and 
ESM (Environmental Services Module) Firmware, information regarding component dependencies, and resolved issues.                
                
                
1.1 Archive Description         
--------------------            
The archive files use the following naming convention:          
Eyyxx_nnnnnnnn.zip or Eyyxx_nnnnnnnn.tar.gz             
                
yy = first two digits of the E-Series or EF-Series model name           
nnnnnnnn = Controller OS package version                
                
xx in the filename indicates that the files pertain to all controller-drive models for a particular controller model            
                
For example, the following archives contain code packages for the E5512, E5524, E5560, and EF550 storage systems:             
                
E55xx_08200500.zip              
E55xx_08200500.tar.gz           
                
                
1.2 Package Contents            
--------------------            
The archive files for this release contain the following:            
                
- RC_08202000_e10_820_xxxx.dlp
- esm039E.esm   
- Nxxxx-820834-DBA.dlp  (Controller NVSRAM - Dual Controller version)           
- Nxxxx-820834-SBA.dlp  (Controller NVSRAM - Single Controller version)*         
          
                
xxxx is the controller board ID.  Refer to the archive name to ensure you have the correct package for your controller model (see section 1.1 for details)              
*Single Controller NVSRAM is only included for those controller models that support single-controller operation

1.3 Component Version Formatting
--------------------
The following table describes the component version naming convention.  YY indicates identical numbering for a major release.

  ______________________________________________________________________________       
 |Component                             |Version Format                         |
 |______________________________________________________________________________|
 |SANtricity OS                         |08.YY                                  |
 |______________________________________________________________________________|
 |SANtricity Storage Manager            |11.YY**                                |
 |______________________________________________________________________________|
 |Volume Snapshot Service (VSS)         |S0YY                                   |
 |______________________________________________________________________________|
 |Virtual Disk Service (VDS)            |D0YY                                   |
 |______________________________________________________________________________|
 |VSS+VDS (package)                     |10YY                                   |
 |______________________________________________________________________________|
 |Redundant Dual Active                 |Use the package posted with the        |
 |Controller (RDAC)                     |SANtricity Storage Manager             |
 |______________________________________________________________________________|
 
**NOTE: If a later SANtricity Storage Manager installer version 11.ZZ is available, it will be backward compatible with 08.YY SANtricity OS.  
 

1.4 Software Dependencies
--------------------
When you update a system with one component from a release, make sure that you update all components
from that release. Although there is backward compatibility between some of the components, certification
of the software, firmware, and drivers is done as a bundle. 

The following table shows the specific SANtricity components and versions that were certified together
for this release. These software versions are available on the NetApp Support Site.

  ______________________________________________________________________________________
 |Software Component                    |Filename                                       |
 |______________________________________________________________________________________|
 |E5600 Series Firmware                 |E56xx_08202000.zip                             |
 |                                      |E56xx_08202000.tar.gz                          |
 |______________________________________________________________________________________|
 |EF560 Flash Array Firmware            |E56xx_08202000.zip                             |
 |                                      |E56xx_08202000.tar.gz                          |
 |______________________________________________________________________________________|
 |E5500 Series Firmware                 |E55xx_08202000.zip                             |
 |                                      |E55xx_08202000.tar.gz                          |
 |______________________________________________________________________________________|
 |EF550 Flash Array Firmware            |E55xx_08202000.zip                             |
 |                                      |E55xx_08202000.tar.gz                          |
 |______________________________________________________________________________________|
 |E5400 Series Firmware                 |E54xx_08202000.zip                             |
 |                                      |E54xx_08202000.tar.gz                          |
 |______________________________________________________________________________________|
 |EF540 Flash Array Firmware            |E54xx_08202000.zip                             |
 |                                      |E54xx_08202000.tar.gz                          |
 |______________________________________________________________________________________|
 |E2700 Series Firmware                 |E27xx_08202000.zip                             |
 |                                      |E27xx_08202000.tar.gz                          |
 |______________________________________________________________________________________|
 |E2600 Series Firmware                 |E26xx_08202000.zip                             |
 |                                      |E26xx_08202000.tar.gz                          |
 |______________________________________________________________________________________|
 |SANtricity Storage Manager                                                            |
 |______________________________________________________________________________________|
 |                          Windows SMIA|SMIA-WS32-11.30.0300.0004.exe                  |
 |                                      |SMIA-WinX64-11.30.0300.0004.exe                |
 |______________________________________________________________________________________|
 |     32-bit Linux SMIA and Native Pkgs|SMIA-LINUX-11.30.0A00.0004.bin                 |
 |                                      |SMclient-LINUX-11.30.0G00.0004-1.noarch.rpm    |
 |                                      |SMesm-LINUX-11.30.0G00.0000-1.noarch.rpm       |
 |                                      |SMruntime-LINUX-11.30.0A00.0001-1.i586.rpm     |
 |______________________________________________________________________________________|
 |  Linux PPC 64LE SMIA                 |SMIA-LINUXPPCLE-11.30.0A00.0004.bin            |
 |    and Native Pkgs                   |SMclient-LINUX-11.30.0G00.0004-1.noarch.rpm    |
 |                                      |SMesm-LINUX-11.30.0G00.0000-1.noarch.rpm       |
 |                                      |SMruntime-LINUX-11.30.0A00.0001-1.ppc64le.rpm  |
 |______________________________________________________________________________________|
 | 64-bit x86 Linux SMIA and Native Pkgs|SMIA-LINUXX64-11.30.0A00.0004.bin              |
 |                                      |SMagent-LINUX-11.30.0A00.0001-1.x86_64.rpm     |
 |                                      |SMclient-LINUX-11.30.0G00.0004-1.noarch.rpm    |
 |                                      |SMesm-LINUX-11.30.0G00.0000-1.noarch.rpm       |
 |                                      |SMruntime-LINUX-11.30.0A00.0001-1.x86_64.rpm   |
 |                                      |SMutil-LINUX-11.30.0A00.0001-1.x86_64.rpm      |
 |______________________________________________________________________________________|
 | 64-bit PPC Linux SMIA and Native Pkgs|SMIA-LINUXPPC-11.30.0A00.0004.bin              |
 |                                      |SMagent-LINUX-11.30.0A00.0001-1.ppc64.rpm      |
 |                                      |SMclient-LINUX-11.30.0G00.0004-1.noarch.rpm    |
 |                                      |SMesm-LINUX-11.30.0G00.0000-1.noarch.rpm       |
 |                                      |SMruntime-LINUX-11.30.0A00.0001-1.ppc64.rpm    |
 |                                      |SMutil-LINUX-11.30.0A00.0001-1.ppc64.rpm       |
 |______________________________________________________________________________________|
 |                              AIX SMIA|SMIA-AIX-11.30.0600.0004.bin                   |
 |                              AIX MPIO|disk.fcp.netapp_eseries.01.00.0600.0002.bff    |
 |______________________________________________________________________________________|
 |                          Sol x86 SMIA|SMIA-SOLX86-11.30.0000.0004.bin                |
 |                                      |SMIA-SOL-11.30.0000.0004.bin                   |
 |______________________________________________________________________________________|
 |                                   MIB|SM10_R3.MIB                                    |
 |______________________________________________________________________________________|


NOTE: When updating the system, update the SANtricity Storage Manager software first, and then update the SANtricity OS. For more
information, see the E-Series Storage System Upgrade Guide.

1.5 Installation 
--------------------
For detailed installation instructions, please refer to the following user guides available on the NetApp Support Site, http://mysupport.netapp.com/eseries

  Express Guides
  Software Installation Reference Guide
  System Upgrade Guide
                
                
2. Resolved Issues
======================================================
The following issues have been resolved in SANtricity OS, NVSRAM, or ESM firmware

September 2016 -------------------------------------------------------------------------------------------------------
SANtricity OS  package version 08.20.20.00
ID              Affected Component      Sev     Description     
200840081       SANtricity OS           1       Failed VMware Vmotion read operation caused data inconsistency
200818717       SANtricity OS           1       Controller reboot during volume initialization caused data inconsistency
200881413       SANtricity OS           1       Brocade RDP polling causes controllers to log out, causing path failures
200886697       SANtricity OS           1       A controller reboot at a specific time during drive reconstruction caused data inconsistency 
200895878       SANtricity OS           1       Cobra-D drives return 1/18/6 check conditions, associated data integrity issues, 100A MEL event reported
200823455       SANtricity OS           2       Unlikely scenario with a flaky drive and a controller error caused increased latency to a drive
200866841       SANtricity OS           2       Controller reboot due to Fabric congestion
200872171       SANtricity OS           2       Volume does not complete reconstruction after drive failure if Disk Pool almost full
200878701       SANtricity OS           2       Timing window with simultaneous drive PFA and drive write failure leads to data inconsistency
200880811       SANtricity OS           2       Internal error during daily ASUP Collections
200828852       SANtricity OS           2       On AIX, Auto Contingent Allegiance (ACA) not being cleared by LUN Reset
200870546       SANtricity OS           2       Multiple CLI commands caused controller panic and reboot
200889994       SANtricity OS           2       Media scan is disabled by default on thin volumes
200890962       SANtricity OS           2       Unresponsive controller with Windows ODX or VMware VAAI, SSD Cache enabled and Data Assurance disabled on source volume.
200883163       NVSRAM                  NA      Enable Critical MEL for forcibly disabled Write Back caching

May 2016 -------------------------------------------------------------------------------------------------------
SANtricity OS  package version 08.20.18.00
ID         Affected Component   Sev     Description
200806769  SANtricity OS        1       Hot spare drive failure after copyback, but before completion event is processed, caused data inconsistency
200811286  SANtricity OS        1       Controller reboot when recovering a failed mirrored volume with thin volumes, mirroring and snapshots in use
200817406  SANtricity OS        1       A forced transfer from a host during cache restore after array power cycle caused data inconsistency
200827603  SANtricity OS        1       With 20+ drives per VG, >1GB volumes and small segment size, data inconsistency occurred after Dynamic RAID Migration
200838467  SANtricity OS        1       Controller reboot due to contention between IO to the cache backup device and the back-end drives
200844520  SANtricity OS        1       Data assurance lockdown with large IO size and SSD Cache, when using the Multimedia cache setting
200847708  SANtricity OS        1       Data inconsistency with queue depth per controller > 1000, small IOs, and read from the alternate due to path failure (ALUA)
200860238  SANtricity OS        1       Under precise timing conditions, a forced transfer from a host after controller power cycle caused data loss 
200627785  SANtricity OS        2       Controller failure during array power-up or controller reboot
200728664  SANtricity OS        2       With FC and high workload (>1000 Ios per host port), a link down event or slow credit condition caused a controller reboot
200808934  SANtricity OS        2       Controller reboot caused by path failure to remote storage array in mirror relationship
200830164  SANtricity OS        2       Online Drive Firmware Upgrade with IO fails and causes degraded volumes
200837167  SANtricity OS        2       Events 2046 and 2061 reported in the event log with Windows 2012, ODX and Data Assurance enabled, and write cache disabled
200851908  SANtricity OS        2       Under certain timing and workload conditions, a Dynamic Volume Expansion on an asynch mirrored pair fails the mirror
200860729  SANtricity OS        2       Drive timeouts (b/44 check condition)
200792986  ESM Firmware         1       faulty connector or ESM not fully inserted caused dual ESM reboot, loss of tray access
200817698  ESM Firmware         2       Non-owning ESM panic and reboot due to invalid drawer state
N/A        NVSRAM               N/A     Changes to support future development


February 2016 -------------------------------------------------------------------------------------------------------
SANtricity OS  package version 08.20.16.00
ID         Affected Component           Sev     Description
200790440  SANtricity OS                Enh     During dual controller replacement (upgrade), compare xa.bb.cc.dd on controller and drives instead of only xa.bb to determine whether to perform auto code sync
200792037  SANtricity OS                1       VxWorks is vulnerable to security vulnerability CVE-2015-3963
200796533  SANtricity OS                1       A hot spare drive failing at the instant copyback completes causes data inconsistency
200664467  SANtricity OS                1       An unexpected controller reboot during cache backup following a power outage may cause data inconsistency 
200816068  SANtricity OS                1       In rare circumstances, a high rate of incoming Persistent Reservations leads to controller deadlock, requiring a target reset
200735465  SANtricity OS                2       Receive queue starvation in IB iSER configuration results in loss of iSCSI connectivity to controller
200788652  SANtricity OS                2       With 8GB or 16GB FC, a controller panic and reboot was encountered when an unsupported HBA sent an invalid task mgmt cmd
200793562  SANtricity OS                2       Performance degredation for 30 seconds every 15 minutes
200785518  SANtricity OS                2       iSCSI HIC chip reboot causes controller reboot
200784339  SANtricity OS                2       Pressing the "Refresh DHCP" button in iSCSI settings dialog causes controller reboot due to data abort fault
200775700  SANtricity OS                2       Upgrading controller firmware with no FC SFPs installed causes superfluous debug messages
200782508  SANtricity OS                2       Controller reboot due to page fault when replacing a failed drive
200796914  SANtricity OS                2       With iSCSI HICs, a controller reboot occurred while gathering internal debug data for enhanced Ethernet statistics
200803207  SANtricity OS                2       With iSCSI or IB-iSER, upper-case characters in the CHAP username sent from the host causes a CHAP authentication failure
200807294  SANtricity OS                2       Unable to transfer volume ownership if misbehaving drives fails to spin up after power cycle
200808937  SANtricity OS                2       Multiple iSCSI driver aborts with mirroring on E5400/EF540 lead to controller reboots, failover issues
200808024  SANtricity OS                2       Intermittent battery failure with battery cell imbalance (cell over voltage)
200797322  SANtricity OS                2       Controller panic and reboot with fast drive pull/push (not waiting the recommended 30 seconds)
200818795  SANtricity OS                2       Transitioning virtual DDP drives from failed to optimal state without reconstruction causes data loss
200822035  SANtricity OS                2       Performance degredation with heavy sequential writes and misbehaving drive fails to spin up
200649038  SANtricity OS                N/A     Better handling of drive replacement in large disk pools.

October 2015 -------------------------------------------------------------------------------------------------------
SANtricity OS  package version 08.20.12.00
ID         Affected Component                      Sev     Description
200712374  SANtricity OS                           1       In extremely rare circumstances, a DVE/DCE operation causes a data inconsistency or PI reftag error
200732658  SANtricity OS                           1       Workaround for issue with Seagate 6TB Makara HDDs that can lead to PI errors or data inconsistencies
200746168  SANtricity OS                           1       A Windows 2012 ODX Zero token write with a reconfiguration operation in progress, snapshots or mirrors enabled on the storage, caused data inconsistencies or controller lockdown
200771318  SANtricity OS                           1       On E5500, E5600, EF550 or EF560, with a newly created volume (IAF), a drive failure can cause PI errors
200782473  SANtricity OS                           1       On E5500, E5600, EF550 or EF560, a controller reboots if a host is using Persistent Reservations and aborts a command
200792033  SANtricity OS                           1       Critical security vulnerability (CVE-2015-7599) in the VxWorks portion of Santricity OS (Controller Firmware)
200747058  SANtricity OS                           2       Adjust E6600 fan speeds to avoid Hitachi Mars K-plus drives overheating
200757665  SANtricity OS                           2       With E2600, many LUN mapping changes caused one controller to lock down during a controller firmware upgrade
200762549  SANtricity OS                           2       Using an Infiniband HIC with SCSI RDMA Protocol (SRP), an error in a host read command caused a controller reboot
200765520  SANtricity OS                           2       A telnet session initiated with the controller caused a Page Fault (controller reboot)
200766846  SANtricity OS                           2       DDP failure when selecting 'yes' if 'add capacity' dialog is erroneously presented after replacing a failed drive.


September 2015 -------------------------------------------------------------------------------------------------------
SANtricity OS  package version 08.20.11.00
ID         Affected Component                      Sev     Description
200682552   SANtricity OS                          1     Data inconsistency with SSD Cache enabled and a read during IAF (Immediate Availability Format)
200718095   SANtricity OS                          1     Controller reboot due to Ancient IO with large Dynamic Disk Pool (> 120 drives) and heavy IO
200734209   SANtricity OS                          1     Controller reboot during write with Rapid Reconstruction pending on the volume causes data loss
200741720   SANtricity OS                          1     Make changes to the IB driver to prevent data corruption issues with future updates to initiator IB drivers
200745455   SANtricity OS                          1     Controller lockdown when Data Assurance is enabled on E5400 with RAID 1, and an operation in progress such as Immediate Availability Format, Dynamic Capacity Expansion, etc.
200751465   SANtricity OS                          1     Controller reboot due to memory fault after controller reboot with failed drive
200761446   SANtricity OS                          1     With E5500/EF550/E5600/EF560 and SSD drives in the base tray, drives were failed after placing a failed controller online
200583853   SANtricity OS                          2     Unreadable sector reported with Data Assurance or data inconsistency without Data Assurance due to memory corruption
200700410   SANtricity OS                          2     Controller reboot after removing a drive from a Dynamic Disk Pool, then re-adding the same drive
200723483   SANtricity OS                          2     Unable to expand Disk Pool volume to utilize remaining free capacity | Error 749 received
200725379   SANtricity OS                          2     Intermittent Power-Fan Canister Termperature Overtemp warnings received
200740150   SANtricity OS                          2     Power loss during dual controller lockdown on E2600 results in data loss
200673730   SANtricity OS                          3     Incorrect version reported for Staged NVSRAM
200733275   ESM Firmware                           2     Intermittent power supply temperature over temp events reported in the Major Event Log with PS temps in the 31-32 C range


May 2015 -------------------------------------------------------------------------------------------------------
SANtricity OS  package version 08.20.09.00
ID         Affected Component                      Sev     Description
200639949  SANtricity OS                           1       Data Assurance errors during Windows Offloaded Data Transfer (ODX)
200653743  SANtricity OS                           1       Data inconsistency after changing iSCSI parameters
200656120  SANtricity OS                           1       Controllers did not complete Start of Day after power cycle with DDP volumes
200683146  SANtricity OS                           1       Data Assurance errors after controller reboot with double-degraded RAID 6 volumes
200691195  SANtricity OS                           1       Configuration data lost during controller reboot with HW errors
200710156  SANtricity OS                           1       In a Clustered environment, Windows Offloaded Data Transfer (ODX) returns good status even though it was not successfully completed
200701031  SANtricity OS                           2       Data Assurance errors during XCOPY (Windows ODX or VMWare VAAI) with Mirroring and SSD Cache enabled
200676598  SANtricity OS                           2       Slow Support Bundle Collection with possible controller reboot caused by back-end errors or drive timeouts
200687792  SANtricity OS                           2       Media Scan causes data in cache to be flushed to disk without a Data Assurance check 
200697779  SANtricity OS                           2       Controller reboot during ASUP collection after Snapshots are set to read/write
200709915  SANtricity OS                           2       Long DDC collection time on E2600 controller causes extended start-of-day and loss of access
200663470  ESM Firmware                            2       Degraded Drawer reported after upgrading ESM firmware on DE6600
N/A        Controller NVSRAM                       2       Re-enable Windows Offloaded Data Transfer (ODX)

May 2015 -------------------------------------------------------------------------------------------------------
SANtricity OS  package version 08.20.08R1
ID         Affected Component                      Sev     Description
N/A        Controller NVSRAM                       1       Temporarily disable Windows Offloaded Data Transfer (ODX) until a late May release (with a permanent fix) to prevent an issue in Windows 2012 clustered environments where an ODX copy returns good status even though it was not successfully completed

March 2015 -------------------------------------------------------------------------------------------------------
SANtricity OS  package version 08.20.08.00 
ID         Affected Component                      Sev     Description
200595945  SANtricity OS                           1       A power cycle with multiple cache backup devices in use may result in an incomplete flush of backed up cache data to disk
200600360  SANtricity OS                           1       Data corruption in the highly unlikely case that an assigned drive is power-cycled just before a controller reboots
200650556  SANtricity OS                           1       Data Corruption with large IO size during volume reconfig operation (DVE, DCE) and Snapshot volumes present
200656147  SANtricity OS                           1       Database corruption with DDP, a failed drive and a drive extent allocation failure during reconstruction
200650614  SANtricity OS                           1       Controller reboot when using VAAI XCOPY with marginal drives and Data Assurance enabled
200625208  SANtricity OS                           1       Controllers Panic when disabling Data Assurance (DA/PI) with Thin Provisioned Volumes
200667219  SANtricity OS                           1       Loss of access after controller reset for iSCSI systems with LUN mappings not in the default group and failure of RVM mirrors
200674994  SANtricity OS                           1       Controller lockdown with a DDP close to full if a drive is replaced with a larger capacity drive and a controller is reset
200620293  SANtricity OS                           2       Loss of data access may occur if a link tranfer error occurs while the host is accessing a volume through the non-owning path
200604472  SANtricity OS                           2       With a large DDP, a controller reboots when a failed drive is replaced while recontruction is still occurring
200669301  SANtricity OS                           2       Controller reboot during ASUP or Support Bundle collection
200670427  SANtricity OS                           2       FC Host detected IO timeout during State Capture or ASUP collection with highly loaded system (queue depth > 64)
200629996  SANtricity OS                           2       Controller reboot during manual Support Bundle or ASUP collection with SSD Cache and "Database" cache settings
200624827  SANtricity OS                           3       Spurious "Drive returned CHECK CONDITION" messages reported in the Major Event Log
200618791  SANtricity OS                           3       Erroneous WB_CACHING_FORCIBLY_DISABLED message reported in the Recovery Guru after the array has returned to an optimal state
874015     Controller NVSRAM                       1       ONTAP not handling 06/8b/02 check condition from E-Series and failing the LUNs
N/A        Controller NVSRAM                       N/A     Enable background media scan for newly created volumes

December 2014 -------------------------------------------------------------------------------------------------------
SANtricity OS  package version 08.20.05.00 
ID         Affected Component                      Sev     Description
200482754  SANtricity OS                           1       Controller Lockdown With SSD Cache, DA Enabled, and IAF in Progress
200468071  SANtricity OS                           2       In rare circumstances, a controller firmware upgrade may result in a degraded drive tray.
200433587  SANtricity OS                           2       Can't automatically create a DA-capable DDP if non-DA drives are included in candidate list
200488228  SANtricity OS                           2       Additional Controller Reboot During Storage System Power Cycle with iSCSI and Asynchronous Remote Volume Mirroring
200492307  SANtricity OS                           2       Failed SAS Port After Controller Replacement with Used Controller
200482741  SANtricity OS                           2       Drive Remains "Replaced" After Reconstruction Complete
200484066  SANtricity OS                           2       Dynamic Disk Pool Remains in Degraded State After Recovering from Drive Issue During Dynamic Capacity Reduction Operation
200488357  SANtricity OS                           2       Erroneous Event 7A00 Logged in Major Event Log After Upgrade to 8.10 Controller Firmware
200460081  SANtricity OS                           3       Changing the IP address of an iSNS registration to an invalid address can temporarily report a "good" status.

                
3. Revision History             
====================    
* Rev 08.20.05.00  (December 2014)
* Rev 08.20.08.00  (March 2015)
* Rev 08.20.08R1   (May 2015)
* Rev 08.20.09.00  (May 2015)
* Rev 08.20.11.00  (September 2015)
* Rev 08.20.12.00  (October 2015)
* Rev 08.20.16.00  (February 2016)
* Rev 08.20.18.00  (May 2016)
* Rev 08.20.20.00  (September 2016)

4. Trademark information
====================    
NetApp, the NetApp logo, Go Further, Faster, AltaVault, ASUP, AutoSupport, Campaign Express,
Cloud ONTAP, Clustered Data ONTAP, Customer Fitness, Data ONTAP, DataMotion, Fitness, Flash
Accel, Flash Cache, Flash Pool, FlashRay, FlexArray, FlexCache, FlexClone, FlexPod, FlexScale,
FlexShare, FlexVol, FPolicy, GetSuccessful, LockVault, Manage ONTAP, Mars, MetroCluster,
MultiStore, NetApp Insight, OnCommand, ONTAP, ONTAPI, RAID DP, RAID-TEC, SANtricity,
SecureShare, Simplicity, Simulate ONTAP, Snap Creator, SnapCenter, SnapCopy, SnapDrive,
SnapIntegrator, SnapLock, SnapManager, SnapMirror, SnapMover, SnapProtect, SnapRestore,
Snapshot, SnapValidator, SnapVault, StorageGRID, Tech OnTap, Unbound Cloud, and WAFL and
other names are trademarks or registered trademarks of NetApp, Inc., in the United States, and/or
other countries. All other brands or products are trademarks or registered trademarks of their
respective holders and should be treated as such. A current list of NetApp trademarks is available on
the web.
http://www.netapp.com/us/legal/netapptmlist.aspx
IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines
Corporation in the United States, other countries, or both. A complete and current list of other IBM trademarks is
available on the web at http://www.ibm.com/legal/copytrade.shtml.
Apple is a registered trademark and QuickTime is a trademark of Apple, Inc. in the United States and/or other
countries. Microsoft is a registered trademark and Windows Media is a trademark of Microsoft Corporation in the
United States and/or other countries. RealAudio, RealNetworks, RealPlayer, RealSystem, RealText, and RealVideo
are registered trademarks and RealMedia, RealProxy, and SureStream are trademarks of RealNetworks, Inc. in the
United States and/or other countries.
All other brands or products are trademarks or registered trademarks of their respective holders and should be treated
as such.
NetApp, Inc. is a licensee of the CompactFlash and CF Logo trademarks.
NetApp, Inc. NetCache is certified RealSystem compatible.