Import/Export Event Codes

The following table provides each import/export event code, its corresponding message, and a description of the message.

Code

Message

Description

100

Import of volume BARCODE into library LIBNAME is complete.

The virtual tape BARCODE has been successfully imported into the virtual library LIBNAME.

100

Exporting volume BARCODE. Volume was not modified after import. No transfer of data is required.

The virtual tape BARCODE was requested to be exported. Export will take place, but as no data was modified since import, contents of volume do not need to be copied. This behavior can be changed by using the Virtual Tapes/Change Export Status command.

100

Failed to migrate VOLUME from SRC to DEST library.

The migration of the virtual tape VOLUME from the source SRC to the destination DEST virtual library failed.

100

Volume BARCODE is already in library LIBNAME. No action was taken.

No action was taken because the virtual tape BARCODE was already in the virtual library LIBNAME.

100

Exporting quick-load volume BARCODE. No transfer of data is required.

No action was taken because the special import instruction to quick load was selected when the physical tape was imported into NearStore VTL.

100

Exporting new empty volume BARCODE. No transfer of data is required.

No action was taken because the virtual tape being exported is new and has no data on it.

100

Exported read-only volume BARCODE. No transfer of data is required.

No action was taken because the virtual tape was created from a virtual tape that was imported as read only; the data has not changed.

100

Export of volume BARCODE from library LIBNAME is complete.

The export of the virtual tape BARCODE from the virtual tape library LIBNAME is complete.

101

Export of volume BARCODE from library LIBNAME failed.

The export of the virtual tape BARCODE from the virtual library LIBNAME failed.

101

Export of volume BARCODE from library LIBNAME failed. Request was aborted.

The export of the virtual tape BARCODE from the virtual library LIBNAME failed because it was aborted.

101

Import of volume BARCODE into library LIBNAME failed.

The import of the virtual tape BARCODE into the virtual library LIBNAME failed.

101

Import of volume BARCODE into library LIBNAME failed. Request was aborted.

The import of the virtual tape BARCODE into the virtual library LIBNAME failed because it was aborted.

102

Aborting the export of volume BARCODE.

The export of the virtual tape BARCODE is being aborted.

102

Aborting the import of volume BARCODE.

The import of the virtual tape BARCODE is being aborted.

102

Aborting the clone of volume BARCODE.

The cloning of the virtual tape BARCODE is being aborted.

102

Aborted the export of volume BARCODE.

The export of the virtual tape BARCODE has been aborted.

102

Aborted the import of volume BARCODE.

The import of the virtual tape BARCODE has been aborted.

103

The request to export volume BARCODE from LIBNAME was added.

An export request for the virtual tape BARCODE from the virtual library LIBNAME has been created.

103

The request to import volume BARCODE into library LIBNAME was added by USERNAME.

The user USERNAME has requested the import of the physical tape BARCODE into the virtual library LIBNAME.

104

Import of volume BARCODE into library LIBNAME added to pick list.

The import of the physical tape BARCODE into the virtual library LIBNAME has been initiated. If the option to use pick lists has been enabled from Configuration Tasks > Advanced, the volume is added to the pick list.

104

Export of volume BARCODE from library LIBNAME added to pick list.

The export of the virtual tape BARCODE from the virtual library LIBNAME has been initiated. If the option to use pick lists has been enabled from Configuration Tasks > Advanced, the volume is added to the pick list.

105

Export of volume BARCODE from library LIBNAME is waiting for an available tape drive.

The export of the virtual tape BARCODE from the virtual library LIBNAME was initiated. The export is pending until there is an available physical tape drive.

105

Import of volume BARCODE into library LIBNAME is waiting for an available tape drive.

The import of the virtual tape BARCODE into the virtual library LIBNAME was initiated. The import is pending until there is an available physical tape drive.

106

Recommend loading physical tape BARCODE into tape drive DEVNAME.

The physical tape BARCODE should be mounted into the physical tape drive DEVNAME.

107

Physical tape BARCODE has been loaded into tape drive DEVNAME.

The physical tape BARCODE has been successfully loaded into the physical tape drive DEVNAME.

108

Physical tape BARCODE is being mounted into tape drive DEVNAME.

The physical tape BARCODE is in the process of being mounted into the physical tape drive DEVNAME.

109

Mount of BARCODE into tape drive DEVNAME failed.

The mount of the physical tape BARCODE into the physical tape drive DEVNAME failed.

110

Import of volume BARCODE into library LIBNAME is in progress.

The import of the virtual tape BARCODE into the virtual library LIBNAME is in progress.

110

Export of volume BARCODE from library LIBNAME is in progress.

The export of the virtual tape BARCODE from the virtual library LIBNAME is in progress.

112

Read encountered EOD because of quick-load.

A read has caused end of data to be reached on a tape imported with the quick-load feature. This can occur because quick load copies only the beginning of tape to disk. If this occurs, volume should be reimported without using quick load.

112

Attempt to space to EOD on quick-load tape.

A space command has caused end of data to be reached on a tape imported with the quick-load feature. This can occur because quick load copies only the beginning of tape to disk. If this occurs, volume should be reimported without using quick load.

113

Physical volume BARCODE not found

The physical volume BARCODE was not found.

Copyright © 1994-2005, Network Appliance, Inc. All rights reserved.
Part number 210-02720_A0
Comments