Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments

FAS900 series systems and GF900 series gateways

FAS900 series and
GF900 series characteristics  Top

The following table lists the characteristics and requirements for your hardware.

Physical characteristics

 

Weight

105 lbs (47.7 kg)

Rack units

6U

Height

10.3 in. (26.2 cm)

Width

17 in. (43.2 cm)

Depth

22 in. (55.9 cm)

Clearance dimensions

 

Front--cooling

All versions

6 in. (15.2 cm)

Rear--cooling

Two-post rack

12 in. (30.5 cm)

Four-post rack

12 in. (30.5 cm)

Front--maintenance

Two-post rack

25 in. (63.5 cm)

Four-post rack

25 in. (63.5 cm)

Rear--maintenance

Two-post rack

40 in. (101.6 cm)

Four-post rack

40 in. (101.6 cm)

Environmental requirements

 

Operating temperature
maximum range

50 F to 104 F
(10 C to 40 C)

Operating temperature
recommended range

68 F to 77 F
(20 C to 25 C)

Nonoperating temperature range

-4 F to 149 F
(-20 C to 65 C)

Relative humidity

10 to 90% noncondensing

Acoustic level

49.5 dBA @ 23 C

Electrical requirements

 

Input voltage, V

100-240

Input current actual, A

3.8-1.95

Input power actual, W

330

Thermal Dissipation, BTU/hr

1,126

Inrush Current, A @ V

30 @ 264

Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments