FAS3000/V3000 series systems

FAS3000/V3000 series characteristics  Top

The following table lists the characteristics and requirements for your hardware.

Physical characteristics

 

Weight

75 lbs (34.019 kg)

Rack units

3U

Height

5.13 in. (13 cm)

Width

17.68 in. (44.9 cm)

Depth

24.33 in. (61.8 cm)

Clearance dimensions

 

Front--cooling

All versions

6 in. (15.2 cm)

Rear--cooling

Two-post rack

12 in. (30.5 cm)

Four-post rack

12 in. (30.5 cm)

Front--maintenance

Two-post rack

30 in. (76.2 cm)

Four-post rack

30 in. (76.2 cm)

Rear--maintenance

Two-post rack

36 in. (91.4 cm)

Four-post rack

36 in. (91.4 cm)

Environmental requirements

 

Operating temperature
maximum range

50 F to 104 F
(10 C to 40 C)

Operating temperature
recommended range

68 F to 77 F
(20 C to 25 C)

Nonoperating temperature range

-4 F to 149 F
(-20 C to 65 C)

Relative humidity

20 to 80% noncondensing

Acoustic level

54 dBA @ 23 C

Electrical requirements

 

Input voltage, V

AC

100-240

DC

-40 to -60

Input current actual, A

AC

3.0-1.6

DC

7.7

Input power actual, W

AC

250

DC

350

Thermal dissipation, BTU/hr

AC

853

DC

1,195

Inrush current, A @ V

AC

35 @ 220

DC

26.5 @ 220