The following table lists the characteristics and requirements for your hardware.
|
Physical characteristics
|
|
|
Weight
|
Fully loaded (six drives)
|
80 lbs (36.29 kg)
|
|
Empty (no drives)
|
72 lbs (32.66 kg)
|
|
Rack units
|
3U
|
|
Height
|
5.13 in. (13 cm)
|
|
Width
|
17.68 in. (44.9 cm)
|
|
Depth
|
24.33 in. (61.8 cm)
|
|
Clearance dimensions
|
|
|
Front--cooling
|
All versions
|
6 in. (15.2 cm)
|
|
Rear--cooling
|
Two-post rack
|
12 in. (30.5 cm)
|
|
Four-post rack
|
12 in. (30.5 cm)
|
|
Front--maintenance
|
Two-post rack
|
30 in. (76.2 cm)
|
|
Four-post rack
|
30 in. (76.2 cm)
|
|
Rear--maintenance
|
Two-post rack
|
36 in. (91.4cm)
|
|
Four-post rack
|
36 in. (91.4 cm)
|
|
Environmental requirements
|
|
|
Operating temperature maximum range
|
50 F to 104 F (10 C to 40 C)
|
|
Operating temperature recommended range
|
68 F to 77 F (20 C to 25 C)
|
|
Nonoperating temperature range
|
-4 F to 149 F (-20 C to 65 C)
|
|
Relative humidity
|
20 to 80% noncondensing
|
|
Acoustic level
|
54 dBA @ 23 C
|
|
Electrical requirements
|
|
|
Input voltage, V
|
AC
|
100-240
|
|
DC
|
-40 to -60
|
|
Input current actual, A
|
AC
|
3.0-1.6
|
|
DC
|
7.7
|
|
Input power actual, W
|
AC
|
250
|
|
DC
|
350
|
|
Thermal dissipation, BTU/hr
|
AC
|
853
|
|
DC
|
1,195
|
|
Inrush current, A @ V
|
AC
|
35 @ 220
|
|
DC
|
26.5 @ 220
|