The following table lists the characteristics and requirements for your hardware.
|
Physical characteristics
|
|
|
Weight
|
90 lbs (40.8 kg)
|
|
Rack units
|
5U
|
|
Height
|
Rack-mount
|
8.6 in. (21.8 cm)
|
|
Tower
|
17.9 in. (45.5 cm)
|
|
Width
|
Rack-mount
|
17.9 in. (45.5 cm)
|
|
Tower
|
9.1 in. (23 cm)
|
|
Depth
|
Rack-mount
|
24.5 in. (62.2 cm)
|
|
Tower
|
24.5 in. (62.2 cm)
|
|
Clearance dimensions
|
|
|
Front--cooling
|
All versions
|
6 in. (15.2 cm)
|
|
Rear--cooling
|
Tower
|
12 in. (30.5 cm)
|
|
Two-post rack
|
19 in. (48.3 cm)
|
|
Four-post rack
|
12 in. (30.5 cm)
|
|
Front--maintenance
|
Tower
|
12 in. (30.5 cm)
|
|
Two-post rack
|
45 in. (114.3 cm)
|
|
Four-post rack
|
32 in. (81.3 cm)
|
|
Rear--maintenance
|
Tower
|
12 in. (30.5 cm)
|
|
Two-post rack
|
19 in. (48.3 cm)
|
|
Four-post rack
|
12 in. (30.5 cm)
|
|
Environmental requirements
|
|
|
Operating temperature maximum range
|
50 F to 95 F (10 C to 35 C)
|
|
Operating temperature recommended range
|
68 F to 77 F (20 C to 25 C)
|
|
Nonoperating temperature range
|
-4 F to 149 F (-20 C to 65 C)
|
|
Relative humidity
|
10 to 90% noncondensing
|
|
Acoustic level
|
45 dBA @ 23 C 5.9 bels @ 23 C
|
|
Electrical requirements
|
|
|
Input voltage, V
|
100-240
|
|
Input current actual, A
|
2.72-1.5
|
|
Input power actual, W
|
256
|
|
Thermal dissipation, BTU/hr
|
874
|
|
Inrush current, A @ V
|
57 @ 115
66 @ 264
|