Before proceeding with the conversion process, you need to know about the cluster concept. Refer to Start Here for a description of the type and sources of information about clusters. For a description about clusters, refer to the Data ONTAP System Administrator's Guide (5.2 or later).
This section describes the software, firmware, and hardware requirements that you must meet for a successful convertion to a cluster.
| Description | Minimum requirements |
|---|---|
| Software | |
| Firmware | Filer firmware |
| Hardware | Upgrades to the F630, F740, or F760 filer pairs and the disk shelves. Refer to Chapter 2 "Hardware Upgrade Process", Appendix A "Optional Hardware Procedures", and the Fibre Channel StorageShelf Hardware Guide for more information. |
Note: Before proceeding with the conversion process, use the "Checklist" to make sure that you have gathered everything that you need.
The following table lists the order of the procedures you must follow for a successful cluster conversion.
Caution: You must follow the order of the procedures listed below. If you fail to follow the specific order described, you can cause permanent damage to your file systems.
| Stage | Process | Purpose | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | Enter sysconfig -r at the consoles of each filer. | Use the resulting output with the "Checklist" to determine the hardware configuration of your filers. | |||||||||
| 2 | Enter sysconfig -v at the consoles of each filer. | Verify the filer and disk firmware versions. | |||||||||
| 3 | Enter ifconfig -a at the consoles of each filer. | Determine the IP addresses of each filer. | |||||||||
| 4 | Back up all your data. | This is an advisable precaution in any conversion process. | |||||||||
| 5 | Verify that both filers have network connections. | The software is on a CD-ROM. You need access to a UNIX or PC system to download the software to the filers. | |||||||||
| 6 | Update each filer to Data ONTAP 5.2.1 software. Refer to the Software and Firmware Upgrade Guide for more information. | ||||||||||
| 7 | At the consoles of each filer, enter halt to shut them down. | You need to do this to upgrade the filer firmware. | |||||||||
| 8 | Update the firmware on your filer. The F630 requires 2.1_a1 and the F700 filers require 2.1_a2. Refer to the Software and Firmware Upgrade Guide for more information. | ||||||||||
| 9 | Reboot the filers and verify the software and filer firmware upgrades. | You need to verify software and firmware upgrades before proceeding to Stage 11. | |||||||||
| 10 |
Verify that the disk firmware fulfils the minimum requirements for a cluster. If not, update the disk firmware by entering disk_fw_update from the console of the filer that owns the disk shelf. Then, shut down each filer by entering halt at the consoles of each filer.
Note: The disk_fw_update command only upgrades the firmware on disks. It does not affect the contents of the disks. | You need to verify firmware upgrades before proceeding to converting the hardware configuration of the filers. | |||||||||
| 11 |
Update the hardware on the filers and disk shelves.
Refer to Chapter 2 "Hardware Upgrade Process" for more information about the required procedures. | ||||||||||
|
the following table details the slot assignments for adapters in filers that are used in clusters.
Note: You need Data ONTAP 5.3 software or later if you intend to install a tape adapter in expansion slot 5 or if you intend to use four Gigabit (GB) Ethernet adapters in each of your filers. | |||||||||||
| Filer | Slot | ||||||||||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | ||
| F630 | Network Interface Adapter (NIA) | 64-bit FC-AL | NVRAM | CI | |||||||
| SCSI Tape | SCSI Tape | ||||||||||
| F740 |
32-bit FC-AL/ NIA | NIA | GBEthernet |
Cluster Interconnect (CI) | |||||||
| F760 |
32-bit FC-AL/ NIA | NIA |
32-bit FC-AL | GB Ethernet |
32-bit FC-AL | ||||||
| 32-bit FC-AL | NIA | SCSI Tape | GB Ethernet | ||||||||
| GB Ethernet | |||||||||||
| 12 | If you have multiple FC-AL adapters labeled Channel A, cable them as Channel A loops. Refer to "How to cable the Channel A loops between your filer and disk shelves in a maximum configuration." | You need to cable the Channel A loops to perform a cf status on each filer. | |||||||||
| 13 | Cable the Channel B loops on the disk shelves but do not complete the loop to the filer. Refer to "How to terminate the Channel B loop in a minimum configuration" and "How to cable the Channel B loop between your disk shelves in a maximum configuration." | Cabling the Channel B loop cards on the disk shelves is a convenience in the clustering process. | |||||||||
| 14 | Turn the filers on and boot them. | The filers are turned on so that you can perform a cf status on each filer. | |||||||||
| 15 | Cable the X ports on the cluster interconnect adapter in each filer and perform a cf status on each filer. | You perform a cf status on each filer to verify the connection between the X ports. | |||||||||
| 16 | Cable the Y ports on the cluster interconnect adapter in each filer and perform a cf status on each filer. | You perform a cf status on each filer to verify the connection between the X and Y ports. | |||||||||
| 17 | Enter halt at the consoles of each filer to shut down the system. | Enter halt at the consoles of each filer to shut down the system. | |||||||||
| 18 | Complete the Channel B loops by using the filer-to-shelf cables to connect the disk shelves to each partner filer and booting the filers. Refer to "How to connect the filers in a minimum configuration" and "How to connect the filers in a maximum configuration." | When you boot both filers, you should be able to see the disks `owned' by the local filer and those `owned' by its partner. | |||||||||
| 19 | Enter boot at the consoles of each filer. | ||||||||||
| 20 | You can now license the cluster. Refer to "How to license clusters" for more information. | You need to license the cluster to enable takeover. | |||||||||
The following checklist provides a list of cluster conversion requirements. If your answer to the second column is No, write your requirements in the third column. Before proceeding with the conversion process, make sure that you have gathered everything that you need.
| Requirements | Yes/ No | What do you need? |
|---|---|---|
| Do the filers have a network connection? | ||
| Do you have Data ONTAP 5.3? | ||
| Do you have Firmware 2.1_a1 for an F630 or 2.1_a2 for an F700? | ||
| Do you have the Software and Firmware Upgrade Guide? | ||
| Do you have the recommended amount of main memory? | ||
| Do you have 32 MB of NVRAM? | ||
| Does your F630 have an FC-AL adapter in expansion slot 8? | ||
| Do you have a differential wide SCSI adapter for external tape devices in expansion slot 6 of your filers? Refer to "Moving or replacing an adapter" for what you need to do. | ||
| Do you have the following hardware components for the conversion? Refer to "Account for and assemble the additional required hardware" for exact requirements. | ||
| Do you have the Fibre Channel StorageShelf Hardware Guide? | ||
| Do you have the following equipment and tools? | ||
| Do you have the following labels that were provided for converting your cluster? | ||