This procedure describes how to configure a pair of mirrored, dual-MAC interfaces, one on each filer in the cluster, so that one can replace the other if one filer fails and is taken over. You do this when converting or installing a filer or when you are adding network connections to a cluster. When you complete this procedure, you will have a NIC in each filer that can take over the connection of the other if there is a takeover.
You must have available the following items:
For LANE, when an adapter is shared, an ELAN cannot be configured more than once on the adapter after takeover. This means that if both filers in a cluster pair are on the same ELANs, each filer needs a minimum of two ATM cards to support full takeover.
To configure a pair of dual-MAC NICs for takeover, complete these steps.
The following command specifies that adapter a4 will takeover all the ELANs on the partner a5 interface.
ifconfig a4 partner a5
Note: If a4 and partner a5 have been configured with common ELANs, then a4 will not take over those ELANs.
A cluster pair might be configured with ELANs as follows:
| Filer and adtapter | Interfaces | Filer and adtapter | Interfaces |
|---|---|---|---|
| filer1-a4 |
el0 default el1 nineKMTU | filer1-a5 | el2 eighteenKMTU |
| filer2-a |
el0 defaul el1 nineKMT | filer2-a5 | el2 eighteenKMTU |
To achieve full takeover, use the following command on one filer:
ifconfig a4 partner a5
and the following command on the other filer:
ifconfig a5 partner a4
Copyright © 1999, Network Appliance, Inc. All rights reserved.
Part No. 210-02334
File: clust4.htm
Last updated: 04/26/99 08:11:41