Monitoring the front operation panel
About monitoring the front operation panel
The front operation panel has five LEDs and a disk shelf ID display. The LEDs indicate whether your disk shelf is functioning normally or there are problems with the hardware. You can also identify any hardware failure associated with the front operation panel of the disk shelf from the error messages displayed on your storage appliance console.
Location of LEDs
The following illustration shows the location of the disk shelf ID display and the front panel LEDs.
Note
The Fault and System LEDs are amber. The other three LEDs are green. See Interpreting the front panel LEDs for an illustrated explanation of how the LEDs function.
Monitoring the disk shelf ID
When you use the thumbwheel switch on the back of the disk shelf to change the disk shelf ID, the disk shelf ID display on the front panel blinks until you power-cycle the disk shelf to make the change take effect.
Interpreting the front panel LEDs
Use the following table to interpret the front panel LEDs.
Fault condition
|
Description
|
LEDs
|
Action item
|
Power
|
Fault
|
Loop A
|
Loop B
|
System
|
N
|
Normal operation
|
Green on
|
Amber off
|
Green on or off
|
Green on or off
|
Amber off
|
None.
|
1
|
LRC A failure
|
Green on
|
Amber off
|
Green off
|
Green on
|
Amber on
|
Check LRC A LED status. See Interpreting LRC module LEDs.
|
2
|
LRC B failure
|
Green on
|
Amber off
|
Green on
|
Green off
|
Amber on
|
Check LRC B LED status.See Interpreting LRC module LEDs.
|
3
|
LRC A loop fault
|
Green on
|
Amber off
|
Green off
|
Green on
|
Amber off
|
Check In and Out port for LRC A. See Interpreting LRC module LEDs.
|
4
|
LRC B loop fault
|
Green on
|
Amber off
|
Green on
|
Green off
|
Amber off
|
Check In and Out port for LRC B. See Interpreting LRC module LEDs.
|
5
|
Enclosure hardware failure
|
Green on
|
Amber off
|
Green on or off
|
Green on or off
|
Amber on
|
Contact Network Appliance customer service.
|
6
|
No SES drive fitted
|
Green on
|
Amber off
|
Green on or off
|
Green on or off
|
Amber flashing
|
Check drives in bays 0 and 1.
|
7
|
Drive Port A bypassed
|
Green on
|
Amber off
|
Green flashing
|
Green on
|
Amber off
|
Check the disk LED. See Interpreting Fibre Channel disk LEDs.
|
8
|
Drive Port B bypassed
|
Green on
|
Amber off
|
Green on
|
Green flashing
|
Amber off
|
Check the disk LED. See Interpreting Fibre Channel disk LEDs.
|
9
|
Any PSU or fan fault
|
Green on
|
Amber on
|
Green on or off
|
Green on or off
|
Amber off
|
Check power supply unit LED panel. See Interpreting power supply LEDs.
|
10
|
Temperature fault
|
Green on
|
Amber on
|
Green on or off
|
Green on or off
|
Amber flashing
|
Check environmental conditions.
|
11
|
Front panel hardware failure
|
Green on
|
Amber off
|
Green flashing
|
Green flashing
|
Amber on
|
Contact Network Appliance customer service.
|
Front operation panel console error messages
The following error messages appear on your storage appliance console if an SES element on the front operation panel fails. For information about replacing a disk shelf, see Replacing a disk shelf in a rack.
Error message
|
Action required
|
Temperature sensor
Element 1: failed
|
The temperature sensor on the front operation panel failed. Contact Network Appliance customer service to replace the disk shelf.
|
Alarm
Element 1: failed
|
The alarm located on the front operation panel failed. Contact Network Appliance customer service to replace the disk shelf.
|
Display
Element 1: failed
|
The alarm located on the front operation panel failed. Contact Network Appliance customer service to replace the disk shelf.
|
Copyright © 1994-2002, Network Appliance, Inc. All rights
reserved.
Part No. 210-00134
File: leds2.htm
Last updated: 07/17/02 02:28:01