The following diagram shows how the local filer and partner filer are cabled into a cluster through the cluster interconnect adapter cables.
Caution
Make sure that you cable the X port on the local filer to the X port on the partner filer. Incorrectly connecting the cluster interconnect adapter ports disables the cluster takeover feature.
To cable your local filer and partner filer into a cluster through the cluster interconnect adapter, complete the following steps.
| 1 | Connect one end of the 4m cluster interconnect cable to the X port on the local filer, and the other end to the X port on the partner filer. |
| 2 | Connect one end of the 4m cluster interconnect cable to the Y port on the local filer, and the other end to the Y port on the partner filer. |
| 3 | Go to section "Step 4: Cabling the Channel B loops." |
Copyright © 1994-2002, Network Appliance, Inc. All rights
reserved.
Part No. 210-02405 B0
File: chapte10.htm
Last updated: 07/22/02 12:18:23