Library Table of Contents Index Previous Next Comments

Verifying your system configuration

Hardware required for clustering  Top

The following tables list all the hardware, including any existing hardware, required to convert your filers into a cluster. See the NOW Web page at http://now.netapp.com for current configuration information.

Filer

The following table lists the minimum and maximum configuration for clustering your filers.

Required hardware

Minimum configuration per filer

Maximum configuration per filer

FC-AL adapters

4

Up to 8

Cluster interconnect adapters (each has two ports: an X port and a Y port)

2

2

Main memory

512 MB

1 GB

NVRAM

32 MB

32 MB

Disk shelves

The following table lists the minimum and maximum hardware configurations for your disk shelves.

Required hardware

Minimum configuration

Maximum configuration

LRC cards:
FC7
FC8
FC9


4
4
4


Up to 48
Up to 24
Up to 12

Disk shelves:
Fibre Channel StorageShelf FC7 only
Fibre Channel StorageShelf FC8 only
Fibre Channel StorageShelf FC9 only
Mix of Fibre Channel StorageShelf FC7, Fibre Channel StorageShelf FC8, and Fibre Channel StorageShelf FC9

Caution
Do not place 18-GB or 36-GB disks into 9-GB disk shelves.


2
2
2
2


Up to 24
Up to 12
Up to 6
The number of disk shelves for both filers must be no greater than the total storage capacity for the filers.

Cables

The following table lists the minumum and maximum number of cables you need to convert your filers into a cluster.

Required hardware

Minimum

Maximum

4m cluster interconnect cables

2

2

1m filer-to-shelf cables:
HSSDC to DB-9 cables


2


Up to 8

0.5m shelf-to-shelf
(DB-9 to DB-9) cables

2

You need (n - l) number of cables, where n is the number of disk shelves and l is the number of loops.

Terminators for FC7 and FC8 only

2

Up to 4

Software requirements  Top

You require the following software to convert your filer to a cluster:

Filer, disk shelf, and disk firmware required for clustering  Top

The following table lists the firmware levels required by your cluster.

Firmware type

Version

Filer

2.3_a2 for F700 series filers

Disk

  • NA05 for the 36-GB, 18-GB, and
    9-GB disk drives
  • NA26 for the 18-GB disk drives
  • 2747 for the 36-GB disk drive
  • FB59 for the 9-GB HH disk drive

Storage shelves

1.1 for Fibre Channel StorageShelf FC7 and FC8

3.1 for Fibre Channel StorageShelf FC9

If your disk is not listed in this table, contact your Customer Support representative for the current firmware version.

For detailed information  Top

You must determine whether your system meets the minimum requirements, as described in the previous tables. To determine your system configuration and firmware levels, see the following sections:

Library Table of Contents Index Previous Next Comments