Library Table of Contents Index Previous Next Comments

Cabling your NetApp system cabinets into a cluster

Step 3: Cabling shelf 0 for takeover

Disk shelf 0 cabling diagram  Top

The following diagram shows how the Channel B shelf 0 on the local filer is cabled to the partner filer and how the Channel B disk shelf 0 on the partner filer is cabled to the local filer.

Cabling disk shelf 0 to the filers  Top

To cable disk shelf 0 of the local filer to the partner filer and vice-versa, complete the following steps.

Step

Action

1

Connect the HSSDC connector to the Channel B FC-AL port on the local filer and connect the other end of the cable to the Channel B LRC Input port on disk shelf 0 of the partner filer.

Note
Because the filer-to-shelf cable is long, it must crisscross behind the vertical trim piece on the rear of the system cabinets.

2

Repeat Step 1 for the partner filer.

3

Go to section Step 4: Completing setup.

Library Table of Contents Index Previous Next Comments