Library Table of Contents Index Previous Next Comments

Cabling your equipment racks into a cluster

Step 2: Cabling the Channel A loops

Channel A loops cabling diagram  Top

The following diagram shows how the filer is cabled to Channel A disk shelf 0 and how the balance of the Channel A shelf-to-shelf loops are cabled.

Cabling the Channel A loops  Top

To cable Channel A loops, complete the following steps.

Step

Action

1

Connect the HSSDC connector to the Channel A FC-AL port on your filer and connect the other end of the cable to the Channel A LRC Input port on disk shelf 0.

2

Label this cable with a solid-colored label.

3

Connect one end of the shelf-to-shelf cable to the Channel A disk shelf 0 LRC Output port, then connect the other end to the Channel A disk shelf 1 LRC Input port.

4

Label this cable with a solid-colored label.

5

Repeat Steps 3 and 4, connecting Channel A disk shelf 1 to Channel A disk shelf 2 and so, on for the remaining disk shelves.

6

Repeat Steps 1 through 5 for the partner filer.

7

Go to section Step 3: Cabling the cluster interconnect adapters.

Library Table of Contents Index Previous Next Comments