To set up the remote portion of the MetroCluster, complete the following steps, using the illustration for reference.
| 1 | Install the node, disks, and switch in the equipment rack or system cabinet at the remote site, as described in Step 2: Installing and preparing the local node and disk shelves. |
| 2 | Configure the switch, as described in Step 3: Configuring the switch. |
| 3 | Connect the SFPs to the ports on the target ports on the switch, then connect the ISL cables to the same ports as used in the local switch. ExampleIf Metro1_switch uses ports 14 and 15, Metro2_switch must use ports 14 and 15 for the ISL connection. Note |
| 4 | Check to make sure that there is a single fabric between the switches by entering the following command: fabricshow Exampletort1_8:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name -------------------------------------------------------- 111: fffc6f 10:00:00:60:69:00:60:11 172.27.100.85 0.0.0.0 "metro1_switch" 222: fffcde 10:00:00:60:69:00:60:12 172.27.100.86 0.0.0.0 "metro2_switch" |
| 5 | Enable the ports on the switch by entering the following command: portenable # |
| 6 | Save the configuration by entering the following command: cfgsave |
| 7 | Check the configuration by entering the following command: cfgshow |
| 8 | Confirm and enable the configuration by entering the following command: cfgenable |
| 9 | Connect the local disk, pool 0 of the mirror, by completing the following steps:
|
| 10 | Connect the partner's remote disk, pool 1 of the mirror, by completing the following steps:
|
| 11 | Connect the FC-AL adapters to the switch by completing the following steps:
|
| 12 | Make sure that you terminate each desk shelf on all the loops. |
Copyright © 1994-2003, Network Appliance, Inc. All rights
reserved.
Part No. 210-00375
File: ch7met10.htm
Last updated: 01/16/03 13:25:53