There are two fan assemblies containing two individual fans. One assembly is near the SCSI backplane in a housing that holds the PCI adapters and swings up on a hinge, and the other fan assembly is attached to the back-panel of the filer. This latter fan housing is used to help secure the PCI adapters in place.
The filer can continue to run with one failed fan, but shuts down if two or more fans fail. You should only replace fans during normal maintenance. The filer must be shut down and unplugged from power sources before you open the filer.
Replacing a system fan consists of the following procedures:
To remove a fan from the fan assembly, complete the following procedures, using the figure for reference.
| 1 | Ground yourself to the filer, then remove the bezel and open the filer as described in Opening the filer. |
|
| 2 | Locate the faulty fan through the error messages displayed on the console. Each fan has an ID number printed directly across from it. |
|
| 3 | Press the release button on the side of the fan, then lift the fan out of the housing. |
|
| 4 | Go to Installing a system fan. |
|
To install a replacement system fan, complete the following steps.
| 1 | Lower the new fan into the fan assembly until it clicks into place. |
| 2 | Close the filer, as described in Closing the filer. |