The system error messages identify conflicts between the hardware and software, or potential operating system problems encountered during boot or operation.
The following table lists the system error messages you might see, provides a brief explanation of what the error message means, and lists the corrective action you need to take to correct the problem.
Address mark not found |
||
Alert! Maximum memory size exceeded. Limiting memory size to 4 GB |
Remove one or more DIMM so that the total memory is 256 MB. See Replacing DIMMs. |
|
Alert! Single-bit
memory error previously
detected in xxxx xxxxh
|
Replace DIMM with a type supported by NetApp. See Replacing DIMMs. |
|
Alert! Previous processor thermal failure |
||
Alert! Primary
processor is out of
rev.
|
The system detected that the primary processor is not the correct revision (defective system board). |
|
Alert! Processor
thermal probe failure
detected
|
||
Alert! Secondary
processor is out of
rev.
|
||
Alert! Uncorrectable memory error previously detected in xxxx xxxxh |
Remove and reseat the DIMMs. If the problem persists, replace the DIMMs. See Replacing DIMMs. |
|
Alert! Unsupported memory in DIMM slot(s) n. |
Unsupported memory module or modules installed in the specified slot. |
Replace one or more DIMM so that all DIMM pairs are the same type. See Replacing DIMMs. |
Attachment failed to respond |
Hard disk drive controller cannot send data to associated drive (defective system board). |
|
Auxiliary device failure |
||
Bad command or file name |
Command entered does not exist, is faulty, or is not in the path name specified. |
|
Bad error-correction code (ECC) on disk read Controller has failed |
||
Boot: Couldn't find NTLDR |
||
CPUs with different level 2 cache sizes detected |
||
Data error |
Replace the hard disk drive. See Replacing disk drives. |
|
Decreasing available memory |
Remove and reseat the DIMM. If the problem persists, replace the DIMM. See Replacing DIMMs. |
|
Diskette drive 0 seek failure |
||
Diskette read failure |
||
Diskette subsystem reset failed |
||
Embedded server management error Embedded server management is not present |
Embedded server management memory might be temporarily corrupted. |
Shut down the system to clear the memory, then restart the system. If the problem persists, call NetApp Customer Support. |
Gate A20 failure |
||
General failure |
Power cycle the filer. If the problem persists, call NetApp Customer Support. |
|
Hard disk controller failure |
Incorrect configuration settings in System Setup program, improperly connected hard disk drive, or faulty hard disk drive controller subsystem (defective system board). |
|
Invalid configuration information - please run SETUP program |
Incorrect configuration settings in System Setup program, or faulty battery. |
Check the System Setup configuration settings. Call NetApp Customer Support. |
Invalid CPU speed detected |
||
Invalid NVRAM configuration, resource reallocated |
System detected and corrected a resource conflict when system resources were allocated using the System Setup program. |
|
I/O parity interrupt at address |
Reinstall the expansion card. If the problem persists, replace the expansion card. See Installing or replacing expansion adapters. |
|
Keyboard controller failure |
||
Keyboard failure Keyboard data line failure |
||
Memory address line failure at address, read value expecting value Memory double word logic failure at Memory odd/even logic failure at address, read value expecting value Memory write/read failure at address, read value expecting value |
Remove and reseat the DIMM. If the problem persists, replace the DIMMs. See Replacing DIMMs. If the problem still persists, call NetApp Customer Support. |
|
Memory allocation error Faulty application Restart the application. Memory parity interrupt at address |
Remove and reseat the DIMMS. If the problem persists, replace the DIMMs. See Replacing DIMMs. |
|
Memory tests terminated by keystroke |
||
No boot device available |
Verify that all hardware is properly installed. If the problem persists, call NetApp Customer Support. |
|
No boot sector on hard- disk drive |
Incorrect configuration settings in System Setup program, or no operating system on hard disk drive. |
Verify that the hard disk drive System Setup information is correct. If the problem persists, replace the NVRAM 4 adapter, as described in Installing or replacing expansion adapters. |
No timer tick interrupt |
||
Non-system disk or disk error |
Verify that all hardware is properly installed. If the problem persists, call NetApp Customer Support. |
|
Not a boot diskette |
||
Processor in socket 1 not installed! |
||
Read fault Requested sector not found |
Replace the NVRAM 4 adapter, as described in Installing or replacing expansion adapters. |
|
Reset failed |
Check that the hard disk drive carriers and the power connector are all properly connected to the SCSI backplane board. Reinstall the hard disk drive. Check all cable connections to the SCSI backplane board. |
|
ROM bad checksum = address |
Reinstall the expansion card. If the problem persists, replace the expansion card. See Installing or replacing expansion adapters. If the problem persists, call NetApp Customer Support. |
|
Sector not found |
||
Seek error |
||
Seek operation failed |
||
Shutdown failure |
||
System backplane cable error |
Check the primary and secondary SCSI interface cable connections to the SCSI backplane board. If the problem persists, call NetApp Customer Support. |
|
System backplane error |
Check the interface cable connections to the backplane board. If the problem persists, call NetApp Customer Support. |
|
Time-of-day clock stopped |
||
Time-of-day not set - please run SETUP program |
Incorrect Time or Date settings or defective system battery Check the Time and Date settings. |
See the Software Setup Guide for instructions. If the problem persists, call NetApp Customer Support. |
Timer chip counter 2 failed |
||
Unexpected interrupt in protected mode |
Improperly seated memory modules or faulty keyboard/mouse controller chip set (defective system board). |
Remove and reseat the DIMMs. If the problem persists, replace the DIMMs. See Replacing DIMMs. If the problem persists, call NetApp Customer Support. |
Unsupported CPU detected in Socket n |
Install a correct version of the microprocessor in the specified microprocessor socket. If the problem persists, call NetApp Customer Support. |
|
Unsupported CPU speed in CMOS |
||
Unsupported DIMM installed in the RAID DIMM slot! |
||
Unsupported RAID key detected! |
||
Utility partition not available |
<F10> was pressed during boot, but no utility partition exists on the boot hard disk drive. |
Power cycle the filer and do not touch the keyboard during boot. The utility partition is not supported, |
Warning! Detected mode switch from RAID to SCSI on the onboard RAID channel. Data loss will occur! Press Y to confirm the change; press any other key to cancel. |
||
Write fault Write fault on selected drive |
Replace the hard disk drive. See Replacing disk drives. |
Copyright © 1994-2002, Network Appliance, Inc. All rights
reserved.
Part No. 210-00079
File: chapted2.htm
Last updated: 07/25/02 13:35:16