Boot error messages might appear after the hardware passes all POSTs and the chassis begins to load the operating system.
The following table describes the error messages that might appear on the LCD if the chassis encounters errors while starting up.
Boot error message
|
Explanation
|
Fatal?
|
Corrective action
|
No /etc/rc
|
The /etc/rc file is corrupted.
|
No
|
- At the hostname> prompt,
enter setup.
- As the system prompts for
system configuration
information, use the
information you recorded in
the chassis configuration
information worksheet in the
Getting Started Guide.
For more information about the storage system setup program, see the Data ONTAP System Administrator's Guide.
|
No /etc/rc, running setup
|
The system cannot find the /etc/rc file and automatically starts setup.
|
No
|
As the system prompts for system configuration information, use the information you recorded in the storage system configuration information worksheet in the Getting Started Guide.
For more information about the storage system setup program, see the Data ONTAP System Administrator's Guide.
|
Cannot initialize labels
|
When the system tries to create a new file system, it cannot initialize the disk labels.
|
Yes
|
Usually, you do not need to create and initialize a file system; do so only after consulting Network Appliance Technical Support.
|
Cannot read labels
|
When the chassis tries to initialize a new file system, it has a problem reading the disk labels it wrote to the disks.
This problem can be because the system failed to read the disk size, or the written disk labels were invalid
|
Yes
|
Usually, you do not need to create and initialize a file system; do so only after consulting Network Appliance Technical Support.
|
Disk label processing failed
|
The chassis detects that the disk is not in the correct drive bay.
|
Yes
|
Make sure that the disk is in the correct bay.
|
Dirty shutdown in degraded mode
|
The file system is inconsistent because you did not shut down the system cleanly when it was in degraded mode.
|
Yes
|
Contact Network Appliance Technical Support for instructions about repairing the file system.
|
Halted: firmware too old
|
The disk firmware is an old version.
|
Yes
|
Update the disk firmware by entering the following command:
disk_fw_update
|
No disk controllers
|
The system cannot detect any disk controllers.
|
Yes
|
Turn off power to the chassis and verify that all adapters are properly seated in the appropriate expansion slots.
|
No disks
|
The system cannot detect any disks.
|
Yes
|
Verify that all disks are properly seated in the drive bays.
|
Drive %s.%d not supported
|
%s--The adapter slot number; %d--The disk ID number. The system detects an unsupported disk drive.
|
Yes
|
- Remove the drive
immediately or the system
drops down to the PROM
monitor within 30 seconds.
- Check the System
Configuration Guide at
http://now.netapp.com to
verify support for your disk
drive.
|
FC-AL loop down, adapter %d
|
The system cannot detect the FC-AL loop or adapter.
|
Yes
|
- Identify the adapter by
entering the following
command:
storage show adapter
- Turn off the power on the
chassis and verify that the
adapter is properly seated in
the expansion slot.
- Verify that all Fibre Channel
cables are connected.
|
File system may be scrambled
|
One of the following errors causes the file system to be inconsistent:
|
|
|
- An unclean shutdown when the chassis is in degraded mode and when NVRAM is not working.
|
Yes
|
Contact Network Appliance Technical Support to learn how to start the system from a system boot diskette and repair the file system.
|
- The number of disks detected in the disk array is different than the number of disks recorded in the disk labels. The system cannot start when more than one disk is missing.
|
Yes
|
Make sure that all disks on the system are properly installed in the disk shelves.
|
- The system encounters a read error while reconstructing parity.
|
Yes
|
Contact Network Appliance Technical Support for help.
|
- A disk failed at the same time the system crashed.
|
Yes
|
Contact Network Appliance Technical Support to learn how to repair the file system.
|
Invalid PCI card slot %d
|
%d--The expansion slot number. The system detects a adapter that is not supported by Network Appliance.
|
Yes
|
Replace the unsupported adapter with an adapter that is included in the System Configuration Guide at http://now.netapp.com.
|
Configuration exceeds max PCI space
|
The memory space for mapping PCI adapters has been exhausted, because either
- There are too many PCI adapters in the system
- An adapter is demanding too many resources
|
Yes
|
Verify that all expansion adapters in the chassis are supported.
Contact Network Appliance Technical Support for help. Have a list ready of all expansion adapters installed in the chassis.
|
No network interfaces
|
The system cannot detect any network interfaces.
|
Yes
|
- Turn off the system and
verify that all NICs are seated
properly in the appropriate
expansion slots.
- Run diagnostics to check the
onboard Ethernet port.
If the problem persists, contact Network Appliance Technical Support.
|
ServerNet: wrong pci slot
|
The system detects that the cluster interconnect adapter is in the wrong expansion slot.
|
Yes
|
See the System Configuration Guide at http://now.netapp.com and place the adapter in the approved expansion slot.
|
No NVRAM present
|
The system cannot detect the NVRAM adapter.
|
Yes
|
Make sure that the NVRAM adapter is securely installed in expansion slot 11.
|
Replace NVRAM batteries
|
The NVRAM battery is low. The system shuts down immediately.
|
Yes
|
Replace the battery.
|
Replace %s
|
%s--The number of NVRAM batteries. The R100 chassis has a single NVRAM battery.
|
Yes
|
Replace the battery.
|
NVRAM #n downrev
|
n--The serial number of the NVRAM adapter. The NVRAM adapter is an early revision that cannot be used with the system.
|
Yes
|
Check the console for information about which revision of the NVRAM adapter is required. Replace the NVRAM adapter.
|
NVRAM test failed
|
An error occurred while the system tested the NVRAM.
|
Yes
|
Contact Network Appliance Technical Support if this message appears.
|
Unsupported NVRAM size %dMB
|
%d--The amount of memory on the NVRAM adapter. The specified size is not supported.
|
Yes
|
Verify that the system has 128 MB of NVRAM.
|