images/nav1.gif (4223 bytes)

Legal Information
Copyright
Trademarks
Support note
Communications regulations
Contact Information
Preface
Safety Information
Overview of the Diagnostics Guide
About diagnostics
Optional materials
Booting the diagnostics program
Booting from FLASH
Booting from CompactFlash
Booting from a diskette
Running Diagnostics
Diagnostic Monitor user interface
Diagnostics menu options
Commands menu options
Options menu options
Running diagnostic tests
Running all diagnostic tests
Running individual diagnostic tests
Test results
Diagnostics Menus
Motherboard diagnostics
C1200 motherboard tests
C2100 motherboard tests
F85 motherboard tests
F87 motherboard tests
F800 series/C3100/C6100/R100 motherboard tests
FAS900 series motherboard tests
Main memory diagnostics
Card diagnostics
ATM diagnostics
DAFS diagnostics
Cluster interconnect diagnostics
Ethernet diagnostics
FC-AL diagnostics
FDDI diagnostics
Gigabit diagnostics
NVRAM diagnostics
RMC diagnostics
SCSI diagnostics
Floppy drive diagnostics
CompactFlash card diagnostics
Stress diagnostics
Error Messages
Error message coding conventions
DAH0001 through DAH0387
DAS0014 through DAS0015
DAU0004
DBH0301 through DBH0501
DBS0307
DEH0001 through DEH0216
DES0007 through DES0022
DFH0001 through DFH0032
DGH0001 through DGH0285
DGS0006
DHH0001
DLH0001 through DLH0100
DMH0001 through DMH0352
DMS0060 through DMS0061
DNH0101 through DNH0550
DNU0002 through DNU0106
DOH0001 through DOH0012
DPH0001 through DPH0029
DRH0001 through DRH0012
DRS0010
DRU0009
DSH0001 through DSH1015
DTH0001 through DTH0053
DTS0002, DTS0003, and DTS0010
DUH0002 through DUH0224
DUS0001
DZH0101 through DZH2002
DZS0430
Environmental Error Messages
C1200 environmental error codes
C2100 environmental error codes
F85 environmental error codes
F87 environmental error codes
F810 environmental error codes
F820/C3100 environmental error codes
F825 environmental error codes
F840/C6100 environmental error codes
F880 environmental error codes
FAS940 environmental error codes
FAS960 environmental error codes
R100 environmental error codes

About diagnostics

The Diagnostic Monitor

The Diagnostic Monitor is a set of diagnostics tools and tests that is used to search for and determine hardware problems. It is used as part of system troubleshooting to help isolate and identify a faulty component or to confirm that a specific component is operating properly.

When to run diagnostics

Typically, you run diagnostics after one of the following events happens on your system:

  • System panic is caused by an unidentified hardware failure
  • Access to a specific device becomes intermittent or the device becomes unavailable
  • System response time becomes sluggish

The following scenarios are examples of when you might run diagnostics:

After the initial hardware installation

When you install your system for the first time, before you boot it, you can check the hardware components by running the all diagnostic. If any problems exist at the hardware level, you can learn about them before you boot the system and connect it to the network.

When the system fails

When the system fails, test the system by first running the all diagnostic and then running individual diagnostics to isolate the cause of the failure.

When adding or replacing hardware

When you add new hardware, such as disk shelves, or change hardware components, before you boot the system, run individual diagnostics, such as fcal, to make sure that the disk shelf connections are sound.

When you replace a suspect component, run an individual diagnostic on the new component to check it before you boot the system. If the problem persists, it is not caused by the suspect component, but lies somewhere else.

If you suspect a problem in a specific hardware area

For example, you observed a lot of error messages of a specific type that point to a problem with the FC-AL connection. This should lead you to run the fcal comprehensive diagnostic while the system is running. If the system passes all tests except for the two tests that require a loopback plug, you might disconnect the system at an appropriate time and run the Loop integrity and Read-only bus tests in extended mode.

Another example is a CPU fan error causing Data ONTAP™ software to panic and shut down the system. When you examine the fan and see that it is spinning, a specific test of the fan might show that the fan is not spinning at the right speed. Replacing the CPU fan should solve the problem.