Diagnostic Monitor user interface
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Options |
|
Count <number> |
(loop selected diagnostic<s> <number> of passes) |
Loop <yes | no> |
(loop selected diagnostic(s)) |
Status <yes | no> (print status messages) |
|
Stop <yes | no> |
(stop-on-error / keep running) |
Xtnd <yes | no> |
(extended tests / regular tests) |
Mchk <auto | off | on | halt> (machine check control) |
|
The following table describes the count and loop options.
| Count and loop options | Description |
|---|---|
count <number> |
You can control how many loop passes are executed. The count option works only when looping is enabled. ExampleTo limit an internal or external loopback test to six loop passes, you would enter: count 6 |
loop no (default) |
Looping is disabled. Terminates session at the end of a pass. Does not continue to loop continuously. |
|
loop yes |
Looping is enabled. The test run loops continuously or for the specified number of loop passes, if you set the count option. Enabled looping applies to the all and run commands. When you enable looping with loop yes, you can also specify the number of loop passes with count <number>. ExampleTo enable looping, you would enter the following command: loop yes **Diagnostic looping enabled The system response tells you looping is enabled. |
The following example enables looping and sets the number of loop passes to six:
loop yes **Diagnostic looping enabled count 6
The following table lists the status option settings.
| Status option | Description |
|---|---|
status yes |
Displays the diagnostic status in detail. |
status no |
Displays the diagnostic status in a brief sentence. |
The following table lists the stop option settings.
Stop option |
Description |
stop yes |
When diagnostics discovers an error, it stops at the end of a complete loop pass. The error is logged to the console terminal. If the stop option is enabled, the diagnostic stops execution at the end of a complete test pass. |
stop no |
When diagnostics discovers an error, it continues running. You can run additional tests and continue to encounter additional errors. |
Extended mode applies only to tests that are marked with the Xtnd label. There are two possible settings, described in the following table.
| Xtnd option | Description |
|---|---|
xtnd no (default) |
In this test mode, called normal test mode, you are testing the system component within the inner boundaries of the unit. |
xtnd yes |
In this test mode, called extended test mode, you are testing the physical media outside the unit. Note: Although loopback plugs are required to run some FC-AL diagnostic tests, they are not required when the Fibre Channel loop has its own terminator. |
This example shows xtnd yes and the system reminding you that you might need loopback plugs and warning you of the consequences of running xtnd yes with NICs.
xtnd yes **Extended testing enabled NOTE: Some diagnostics require loopback plugs for complete test operation and will indicate failures without these plugs!! CAUTION: Do not run these diagnostics on network adapter cards with live network connections. Disconnect all network connections prior to running network diagnostics in Xtnd mode. Running with attached networks can adversely affect other attached devices. Type 'xtnd n' to cancel Extended test mode.
This example shows a test failure when you have done the following:
ERROR DLH0020: FCAL loop is open. Check cables and associated hardware FCAL loop test...........................................FAILED
See Error Messages, for a description of individual error messages.
To prepare for a test in extended mode that requires loopback plugs, complete the following steps.
| Step | Action |
|---|---|
| 1 | Disconnect the system from the network and if applicable from a cluster. |
| 2 | Connect the loopback plugs to the card. |
| 3 | Enable extended mode from the Diagnostic test menu by entering its number: 93 |
| 4 | Run the comprehensive test or the specific loop test. |
| 5 | Remove the loopback plugs after the test is completed. |
The mchk (machine check) option enables you to control system behavior when the hardware detects a machine check error.
The four mchk settings are as follows.
| Mchk option | When a machine check is detected, the system... |
|---|---|
mchk auto |
Automatically chooses the best machine check control for the diagnostic. Usually it halts the diagnostic session. You can use non-default machine check settings in certain memory testing circumstances to aid in diagnosing hardware problems. |
mchk halt |
Halts the system immediately, going into a panic state. Reboot the system to continue running diagnostics. |
mchk no |
Silently ignores the error, unless it is fatal. |
mchk yes |
Does not halt diagnostic execution if memory parity/ECC errors or similar errors are detected. The system reports the machine check and resumes the diagnostic execution. The diagnostic can continue testing and analyzing all errors in the test pass, possibly providing a more accurate callout of memory DIMM failures. |
In the following example, you enable machine check with the mchk yes option.
mchk yes **Machine checks enabled (Display memory machine checks and continue)
You can set the loop, stop, and xtnd options not only at the Diagnostic Monitor menu level, but also at the individual test menu level.
For example, when you enter gbe to run diagnostics on the GbE card, the GbE Diagnostic test menu appears, offering the following test options:
91: |
Enable/disable looping |
92: |
Stop/continue on error |
93: |
Extended/Normal test mode |
You can also enable looping on the card by entering the number for the option:
91
See Diagnostics Menus for more information about individual diagnostic test menus.