images/nav1.gif (4223 bytes)

Legal Information
Copyright
Trademarks
Support note
Communications regulations
Contact Information
Preface
Safety Information
Overview of the Diagnostics Guide
About diagnostics
Optional materials
Booting the diagnostics program
Booting from FLASH
Booting from CompactFlash
Booting from a diskette
Running Diagnostics
Diagnostic Monitor user interface
Diagnostics menu options
Commands menu options
Options menu options
Running diagnostic tests
Running all diagnostic tests
Running individual diagnostic tests
Test results
Diagnostics Menus
Motherboard diagnostics
C1200 motherboard tests
C2100 motherboard tests
F85 motherboard tests
F87 motherboard tests
F800 series/C3100/C6100/R100 motherboard tests
FAS900 series/R150 motherboard tests
Main memory diagnostics
Card diagnostics
ATM diagnostics
DAFS diagnostics
Cluster interconnect diagnostics
Ethernet diagnostics
FC-AL diagnostics
FDDI diagnostics
Gigabit diagnostics
NVRAM diagnostics
RMC diagnostics
SCSI diagnostics
Floppy drive diagnostics
CompactFlash card diagnostics
Stress diagnostics
Error Messages
Error message coding conventions
DAH0001 through DAH0387
DAS0014 through DAS0015
DAU0004
DBH0301 through DBH0501
DBS0307
DEH0001 through DEH0216
DES0007 through DES0022
DFH0001 through DFH0032
DGH0001 through DGH0285
DGS0006
DHH0001
DLH0001 through DLH0100
DMH0001 through DMH0352
DMS0060 through DMS0061
DNH0101 through DNH0550
DNU0002 through DNU0106
DOH0001 through DOH0012
DPH0001 through DPH0029
DRH0001 through DRH0012
DRS0010
DRU0009
DSH0001 through DSH1015
DTH0001 through DTH0053
DTS0002, DTS0003, and DTS0010
DUH0002 through DUH0224
DUS0001
DZH0101 through DZH2002
DZS0430
Environmental Error Messages
C1200 environmental error codes
C2100 environmental error codes
F85 environmental error codes
F87 environmental error codes
F810 environmental error codes
F820/C3100 environmental error codes
F825 environmental error codes
F840/C6100 environmental error codes
F880 environmental error codes
FAS940 environmental error codes
FAS960 environmental error codes
R100 environmental error codes
R150 environmental error codes

Motherboard menu and submenus
Onboard SCSI test menu

This section describes the Onboard SCSI test submenu. The SCSI diagnostic tests can generate error messages associated with the controller and disk shelf.

Note: Tests that are labeled [Xtnd] often require loopback plugs for complete test operation and will indicate failures without these plugs.

Caution: Do not run [Xtnd] mode diagnostics on network adapter cards with live network connections. Disconnect all network connections prior to running network diagnostics in [Xtnd] mode. Running with attached networks can adversely affect other attached devices. Type xtnd n to cancel Extended test mode.

Test no Test Description

1

Comprehensive SCSI test

Runs all tests in this menu in current mode.

2

PCI-PCI bridge test (Netapp)

Verifies the PCI configuration registers.

3

PLX 9060 test (Netapp)

Tests the configuration, self-test, and error status of the PLX9060 bridge.

4

ISP chip test

Verifies the onboard ISP SCSI chip configuration, firmware commands, mailboxes, and status and error information.

5

EEPROM data check (Netapp)

Reads and verifies the serial EEPROM data.

6

SSRAM pattern test (Qlogic)

Tests the on-chip SSRAM with fixed data patterns.

7

SSRAM random test (Qlogic)

Tests the on-chip RAM with random data patterns.

8

SSRAM/DMA pattern test (Qlogic)

Tests the DMA of fixed data patterns between SSRAM and most locations of main memory.

9

SSRAM/DMA random test (Qlogic)

Tests the DMA of random data patterns between SSRAM and most locations of main memory.

10

ISP firmware test (Qlogic)

Tests the ISP firmware (reads and verifies ISP firmware in SSRAM).

11

SCSI interrupt test

Tests the ISP SCSI adapter interrupt.

12

Read-only bus test [Xtnd]

Extended test mode: Tests SCSI adapter loop integrity by reading from each disk attached to the SCSI adapter.

13

Read/write bus test [Mfg]

Option not available.

14

Disk read test

Tests the SCSI adapter connection by reading from each disk attached to the SCSI interface.

15

Disk read/write test

Option not available.

42

Scan and show disks (R100)

Lists the status of all the disks on the specified SCSI adapters. Requires disks attached to the SCSI host adapter on the R100.

71

Show ISP chip info

Displays information about the ISP chip.

72

Show attached SCSI devices

Displays the SCSI devices attached to the system.

73

Show all disks (probe-scsi-all)

Displays all SCSI disks.

74

Reset SCSI adapter

Resets the SCSI adapter.

75

Show serial EEPROM data

Displays the serial EEPROM data.

76

Program serial EEPROM data [Factory]

Option not available.

77

Go to shelf Diagnostics menu

Accesses the disk shelf diagnostics submenu.

78

Set serial # and revision [Factory]

Option not available.

90

SCSI card selection

Enables you to select a specific SCSI card for testing.

91

Enable/disable looping

Enables or disables continuous running of a diagnostic test. The test is stopped when Ctrl-C is pressed or when an error is encountered if option 92 is active.

92

Stop/continue looping on error

Starts or stops running a diagnostic test on an error. If looping is enabled, as set by option 91, looping continues after an error is encountered.

93

Extended/normal test mode

Enables or disables extended mode on tests where extended mode is an available option.

99

Exit

Exits diagnostics.