images/nav1.gif (4223 bytes)

Legal Information
Copyright
Trademarks
Support note
Communications regulations
Contact Information
Preface
Safety Information
Overview of the Diagnostics Guide
About diagnostics
Optional materials
Booting the diagnostics program
Booting from FLASH
Booting from CompactFlash
Booting from a diskette
Running Diagnostics
Diagnostic Monitor user interface
Diagnostics menu options
Commands menu options
Options menu options
Running diagnostic tests
Running all diagnostic tests
Running individual diagnostic tests
Test results
Diagnostics Menus
Motherboard diagnostics
C1200 motherboard tests
C2100 motherboard tests
F85 motherboard tests
F87 motherboard tests
F800 series/C3100/C6100/R100 motherboard tests
FAS900 series/R150 motherboard tests
Main memory diagnostics
Card diagnostics
ATM diagnostics
DAFS diagnostics
Cluster interconnect diagnostics
Ethernet diagnostics
FC-AL diagnostics
FDDI diagnostics
Gigabit diagnostics
NVRAM diagnostics
RMC diagnostics
SCSI diagnostics
Floppy drive diagnostics
CompactFlash card diagnostics
Stress diagnostics
Error Messages
Error message coding conventions
DAH0001 through DAH0387
DAS0014 through DAS0015
DAU0004
DBH0301 through DBH0501
DBS0307
DEH0001 through DEH0216
DES0007 through DES0022
DFH0001 through DFH0032
DGH0001 through DGH0285
DGS0006
DHH0001
DLH0001 through DLH0100
DMH0001 through DMH0352
DMS0060 through DMS0061
DNH0101 through DNH0550
DNU0002 through DNU0106
DOH0001 through DOH0012
DPH0001 through DPH0029
DRH0001 through DRH0012
DRS0010
DRU0009
DSH0001 through DSH1015
DTH0001 through DTH0053
DTS0002, DTS0003, and DTS0010
DUH0002 through DUH0224
DUS0001
DZH0101 through DZH2002
DZS0430
Environmental Error Messages
C1200 environmental error codes
C2100 environmental error codes
F85 environmental error codes
F87 environmental error codes
F810 environmental error codes
F820/C3100 environmental error codes
F825 environmental error codes
F840/C6100 environmental error codes
F880 environmental error codes
FAS940 environmental error codes
FAS960 environmental error codes
R100 environmental error codes
R150 environmental error codes

NVRAM diagnostics
NVRAM3 diagnostics

Rules for running NVRAM on systems with the NVRAM3 card

Observe the following rules when you run the nvram diagnostic on systems with the NVRAM3 card:

  • Do not run this diagnostic immediately after a system crash.
  • Before you run nvram diagnostics, reboot and shut down the system.
  • Be aware that nvram diagnostics overwrite all contents of NVRAM.

You might need to back up the data on the NVRAM before you start nvram diagnostics, because it might not be possible to recover user data from NVRAM after the diagnostic.

You are alerted to be very careful by the following warning:
WARNING!
Do not run the NVRAM diagnostic 
immediately after a system crash or if 
there is a possibility that log data is 
stored. Run only on new boards, or 
after a normal system shutdown, or if 
there is no chance of preserving 
customer data.

NVRAM3 test menu

The following table describes the NVRAM3 test menu.

Test no Test Description

1

Comprehensive NVRAM test

Runs all tests in current mode.

2

Check contents of EEPROM

Verifies contents of onboard EEPROM.

3

Battery voltage check

Checks and displays battery voltage.

4

Memory data walking test

Runs quick test of data lines.

5

Memory address walking test

Runs quick test of all address lines to verify address paths in NVRAM memory.

6

Partial-word load/store test

Tests intermixed data sizes.

7

Memory random data test

Runs longer test by writing and reading random data to all NVRAM locations.

8

Memory random address test

Runs longer test using random addresses.

9

Random 64-bit data test

Runs test on 64-bit random data patterns.

10

ECC data-bits test

Runs ECC data-bits test.

11

ECC check-bits test

Runs ECC check-bits test.

41

Address pattern test

Runs address pattern test on memory addresses.

42

Charger test [Mfg]

Option not available.

71

Show DIMM size

Displays the capacity and size of the DIMMs.

76

Fill for power cycle test, burst read

Fills NVRAM memory with data patterns for power cycle test, which does burst reads.

77

Fill for power cycle test

Fills NVRAM memory with data patterns for power cycle test.

78

Verify data retention

Checks the retention of data in NVRAM after a power cycle. Data comes from data patterns entered in Test 75.

79

Memory read/write

Tests memory for read and write capability.

80

Show serial # and revision

Displays serial number and revision of the NVRAM.

81

Set serial # and revision [Mfg]

Option not available.

82

Display memory by address

Displays the contents of a memory address location.

83

Display onboard EEPROM

Displays information about the onboard EEPROM.

84

Display memory EEPROM

Displays information about the EEPROM dedicated to memory.

85

Show internal registers

Shows the location of the internal memory registers.

86

Set a register [Mfg]

Option not available.

90

NVRAM card selection

Enables the selection of a specific NVRAM card for testing.

91

Enable/disable looping

Enables or disables continuous running of a diagnostic test. The test is stopped when Ctrl-C is pressed or when an error is encountered if option 92 is active.

92

Stop/continue on error

Starts or stops running a diagnostic test on an error. If looping is enabled, as set by option 91, looping continues after an error is encountered.

93

Extended/normal test mode

Enables or disables extended mode on tests where extended mode is an available option.

99

Exit