The following table describes the disk shelf diagnostics submenu for the FC-AL
or SCSI card.
| Test no |
Test |
Description |
1 |
Turn shelf LED on |
Turns on the drive LEDs on the target disk shelf. |
2 |
Turn shelf LED off |
Turns off the drive LEDs on the target disk shelf. |
3 |
Get trunk information |
Displays the list of disk shelves and their firmware revisions on the target FC-AL card. |
4 |
Get shelf drive map |
Displays the list of drives on the disk shelves of the target FC-AL card. |
5 |
Get shelf environment information |
Displays the environmental parameters for the disk shelves on the target FC-AL card. |
6 |
Check SES temperature sensors |
Check SES temperature sensors against threshold value. |
7 |
Check SES FANs |
Check SES fan status. |
8 |
Check SES Power Supply |
Check SES Power Supply status. |
9 |
Check SES ESH (HUB) |
Check SES HUB status on the ESH. |
10 |
Check all SES elements |
Check status of all SES elements in the shelf. |
11 |
Loop integrity/LRC test [Xtnd] |
Extended test mode: Tests the FC-AL loop
integrity and LRC functionality. |
12 |
Show HUB status |
Display status of each port in the HUB for each ESH module. |
70 |
Display sector size for FC-AL devices |
Displays the sector size for the drives on the disk shelves. |
93 |
Extended/normal test mode |
Enables or disables extended mode on tests where extended mode is an available option. |
99 |
Exit this menu |
Returns the user to the main FC-AL menu. |