images/nav1.gif (4223 bytes)

Legal Information
Copyright
Trademarks
Support note
Communications regulations
Contact Information
Preface
Safety Information
Overview of the Diagnostics Guide
About diagnostics
Optional materials
Booting the diagnostics program
Booting from FLASH
Booting from CompactFlash
Booting from a diskette
Running Diagnostics
Diagnostic Monitor user interface
Diagnostics menu options
Commands menu options
Options menu options
Running diagnostic tests
Running all diagnostic tests
Running individual diagnostic tests
Test results
Diagnostics Menus
Motherboard diagnostics
C1200 motherboard tests
C2100 motherboard tests
F85 motherboard tests
F87 motherboard tests
F800 series/C3100/C6100/R100 motherboard tests
FAS900 series/R150 motherboard tests
Main memory diagnostics
Card diagnostics
ATM diagnostics
DAFS diagnostics
Cluster interconnect diagnostics
Ethernet diagnostics
FC-AL diagnostics
FDDI diagnostics
Gigabit diagnostics
NVRAM diagnostics
RMC diagnostics
SCSI diagnostics
Floppy drive diagnostics
CompactFlash card diagnostics
Stress diagnostics
Error Messages
Error message coding conventions
DAH0001 through DAH0387
DAS0014 through DAS0015
DAU0004
DBH0301 through DBH0501
DBS0307
DEH0001 through DEH0216
DES0007 through DES0022
DFH0001 through DFH0032
DGH0001 through DGH0285
DGS0006
DHH0001
DLH0001 through DLH0100
DMH0001 through DMH0352
DMS0060 through DMS0061
DNH0101 through DNH0550
DNU0002 through DNU0106
DOH0001 through DOH0012
DPH0001 through DPH0029
DRH0001 through DRH0012
DRS0010
DRU0009
DSH0001 through DSH1015
DTH0001 through DTH0053
DTS0002, DTS0003, and DTS0010
DUH0002 through DUH0224
DUS0001
DZH0101 through DZH2002
DZS0430
Environmental Error Messages
C1200 environmental error codes
C2100 environmental error codes
F85 environmental error codes
F87 environmental error codes
F810 environmental error codes
F820/C3100 environmental error codes
F825 environmental error codes
F840/C6100 environmental error codes
F880 environmental error codes
FAS940 environmental error codes
FAS960 environmental error codes
R100 environmental error codes
R150 environmental error codes

Card diagnostics
Disk shelf diagnostics submenu

The following table describes the disk shelf diagnostics submenu for the FC-AL or SCSI card.

Note: Tests that are labeled [Xtnd] often require loopback plugs for complete test operation and will indicate failures without these plugs.

Caution: Do not run [Xtnd] mode diagnostics on network adapter cards with live network connections. Disconnect all network connections prior to running network diagnostics in [Xtnd] mode. Running with attached networks can adversely affect other attached devices. Type xtnd n to cancel Extended test mode.

Test no Test Description

1

Turn shelf LED on

Turns on the drive LEDs on the target disk shelf.

2

Turn shelf LED off

Turns off the drive LEDs on the target disk shelf.

3

Get trunk information

Displays the list of disk shelves and their firmware revisions on the target FC-AL card.

4

Get shelf drive map

Displays the list of drives on the disk shelves of the target FC-AL card.

5

Get shelf environment information

Displays the environmental parameters for the disk shelves on the target FC-AL card.

6

Check SES temperature sensors

Check SES temperature sensors against threshold value.

7

Check SES FANs

Check SES fan status.

8

Check SES Power Supply

Check SES Power Supply status.

9

Check SES ESH (HUB)

Check SES HUB status on the ESH.

10

Check all SES elements

Check status of all SES elements in the shelf.

11

Loop integrity/LRC test [Xtnd]

Extended test mode: Tests the FC-AL loop integrity and LRC functionality.

12

Show HUB status

Display status of each port in the HUB for each ESH module.

70

Display sector size for FC-AL devices

Displays the sector size for the drives on the disk shelves.

93

Extended/normal test mode

Enables or disables extended mode on tests where extended mode is an available option.

99

Exit this menu

Returns the user to the main FC-AL menu.