This error message grouping covers hardware errors associated with baseboard
management controller (BMC).
The corrective action for this error message grouping
is below the error
message description.
The following messages can be generated for this message group.
| Error code |
Sample message |
Description |
DTH0001 |
Failed to get the Version Info for current BMC Firmware |
Could not get the version information for the current BMC
firmware. |
DTH0004 |
Failed to Enter BMC Firmware Transfer Mode. Retrying! |
Could not enter BMC firmware transfer mode to start writing the
Flash. |
DTH0005 |
Failed to Write BMC Firmware. Retrying! |
Could not write the BMC firmware to the FLASH. |
DTH0006 |
Failed to Read BMC Firmware |
Could not read BMC firmware from the FLASH. |
DTH0007 |
Failed to Verify newly programmed Firmware! Restarting! |
Could not verify newly programmed firmware in the FLASH. |
DTH0008 |
BMC Firmware is corrupted. Restarting programming! |
BMC firmware is corrupted. |
DTH0009 |
Failed to get the Current SDR Version Information |
Could not get the current version information for the sensor data repository. |
DTH0011 |
Failed to Clear the SDR Repository! Retrying! |
Could not clear the sensor data repository. |
DTH0012 |
Failed to Add a SDR record! Retrying! |
Could not add a sensor data repository record. |
DTH0013 |
Failed to Verify the newly added SDR records! Restarting! |
Could not verify the newly added sensor data repository
records. |
DTH0014 |
Failed to Read a Sensor Record |
Could not read a sensor record from the sensor data repository. |
DTH0015 |
Failed to Read the Sensor Repository Information |
Could not read the sensor repository information. |
DTH0016 |
Failed to Reserve the Sensor Repository |
Could not reserve the sensor repository. |
DTH0017 |
Failed to Read the System Event Log Information |
Could not read the system event log information. |
DTH0018 |
Failed to Read a System Event Log record |
Could not read a system event log record. |
DTH0019 |
Failed to Add a System Event Log record |
Could not add a system event log record. |
DTH0020 |
Failed to Reserve the System Event Log |
Could not reserve the system event log. |
DTH0021 |
Failed to Set the System Event Log timer |
Could not set the system event log timer’s time. |
DTH0022 |
Failed to Get the System Event Log timer |
Could not get the system event log timer’s time. |
DTH0023 |
Failed to Verify the newly written record in the Event Log |
Could not verify the newly written record in the event log. |
DTH0024 |
The BMC Timer is not running at the right speed |
The BMC timer is not running at the right speed. |
DTH0025 |
Failed to get the RTC Time. This is not a BMC Error. |
The real- time clock time could not be read. |
DTH0026 |
Failed to Set the BMC Watchdog Timer |
Could not set the BMC watchdog timer. |
DTH0027 |
Failed to Start the BMC Watchdog Timer |
Could not start the BMC watchdog timer. |
DTH0028 |
Failed to Enable the BMC's NMI generation capability |
Could not enable the BMC's NMI generation capability. |
DTH0029 |
BMC should have generated an NMI but did not |
BMC should have generated an NMI but did not. |
DTH0030 |
Failed to Get the BMC's Device ID |
Could not get the BMC's device identification. |
DTH0031 |
Failed to Get the reason for System Restart |
Could not get the reason for system restart. |
DTH0032 |
Failed to Display text successfully on the LCD |
Could not display text successfully on the LCD. |
DTH0033 |
Failed to Retrieve the BMC's Self Test Information |
Could not retrieve the BMC's self test information. |
DTH0034 |
Failed to Get the System GUID |
Could not get the system GUID. |
DTH0035 |
Failed to Set the System GUID |
Could not set the system GUID. |
DTH0036 |
BMC does not support a Self Test option |
BMC does not support a self test option. |
DTH0037 |
Sensor Data Repository Empty |
Sensor data repository was found to be empty. |
| DTH0039 |
BMC Boot Firmware Code is Corrupted. |
The BMC Boot firmware was found to be corrupted |
| DTH0040 |
BMC FRU internal use area is Corrupted. |
The BMC internal FRU area was found to be corrupted |
| DTH0041 |
Sensor Data Repository is Corrupted. |
The Sensor Data Repository was found to be corrupted |
| DTH0042 |
System Event Log is Corrupted. |
The System Event Log was found to be Corrupted. |
| DTH0043 |
Platform Information Area is Corrupted. |
The BMC Platform Information Area was found to be corrupted. |
| DTH0044 |
BMC FRU device is Inaccessible. |
The BMC FRU device could not be accessed |
| DTH0045 |
BMC Sensor Data Repository is Inaccessible. |
BMC Sensor Data Repository could not be accessed. |
| DTH0046 |
BMC System Event Log is Inaccessible. |
BMC System Event Log could not be accessed |
| DTH0047 |
IPMB Signal Error. |
There was a Signal Error on the BMC Private Bus |
| DTH0048 |
BMC RAM test error. |
BMC RAM had errors during self test |
| DTH0049 |
BMC fatal hardware error. |
The BMC had a fatal internal hardware error. |
| DTH0050 |
Management controller error. |
The BMC had a Management controller error during Self Test |
| DTH0051 |
Private I2C bus error. |
A BMC Private I2C bus had an error. |
| DTH0052 |
BMC internal exception. |
The BMC had an internal error. |
| DTH0053 |
BMC A/D timeout error. |
The BMC analog to digital converter failed to respond |
The following table lists the error message groupings and corrective action that can be taken for the error message group.