This error message grouping covers errors associated with the bridge cards that are in the filer. These
errors are generated when you run the Option 2: Check CPU/Hostbridge CNB20HE status option and Option 3: Check SIO (OSb4) status option from the Motherboard
Diagnostics menu. The corrective action for this error message grouping is below
the error message description.
The following messages can be generated for this message group.
| Error code |
Sample message |
Description |
DBH0301 |
Vendor ID incorrect |
This error message can appear with a variety of cards. Check the test that yielded this error message to determine which bridge is faulty. |
DBH0302 |
Device ID incorrect |
Incorrect bridge chip device ID found during testing. |
DBH0303 |
Base class incorrect |
Incorrect bridge chip base class detected during testing. |
DBH0304 |
Subclass incorrect |
Incorrect bridge chip subclass detected during testing. |
DBH0305 |
Incorrect revision number |
Incorrect bridge chip revision number detected during testing. |
DBH0306 |
Bridge at bus hex_value, slot hex_value has error |
Might indicate an error in the bridge chip, or more likely, a problem with a device on the bus managed by the bridge. |
DBH0308 |
The following bridge error bits could not be located |
Internal bridging software error detected during testing. |
DBH0501 |
No CIOB found on motherboard. |
The motherboard does not have the CIOB. |
To correct the displayed error, replace the card or contact Network Appliance Technical Support.