DES0007 through DES0022
Message type
This error message grouping covers software errors associated with Ethernet cards that are in the filer.
Error message description
The following messages can be generated for this message group.
| Error code |
Sample message |
Description |
DES0007 |
Stop RX and TX process timeout |
Card could not successfully execute the stop transmit receive command. |
DES0016 |
No Ethernet in slot dec_value |
No Ethernet card is installed in the selected slot. |
DES0021 |
No Ethernet in slot dec_value |
No Ethernet card is installed in the selected slot. |
DES0022 |
Counted dec_value ether cards but original scan found dec_value |
Stress test reports that the initialized cards do not match the cards found in the system. |
Corrective action
The following table lists the error message groupings and corrective action that can be taken for the error message group.
| Error message group |
Corrective action |
DES0007 |
- Check that the external loopback plug is connected.
- If it is connected and the card still fails, call Network Appliance Technical Support.
|
DES0016, DES0021-DES0022 |
Replace the Ethernet card or contact Network Appliance Technical Support. |
|