images/nav1.gif (4223 bytes)

Legal Information
Copyright
Trademarks
Support note
Communications regulations
Contact Information
Preface
Safety Information
Overview of the Diagnostics Guide
About diagnostics
Optional materials
Booting the diagnostics program
Booting from FLASH
Booting from CompactFlash
Booting from a diskette
Running Diagnostics
Diagnostic Monitor user interface
Diagnostics menu options
Commands menu options
Options menu options
Running diagnostic tests
Running all diagnostic tests
Running individual diagnostic tests
Test results
Diagnostics Menus
Motherboard diagnostics
C1200 motherboard tests
C2100 motherboard tests
F85 motherboard tests
F87 motherboard tests
F800 series/C3100/C6100/R100 motherboard tests
FAS900 series/R150 motherboard tests
Main memory diagnostics
Card diagnostics
ATM diagnostics
DAFS diagnostics
Cluster interconnect diagnostics
Ethernet diagnostics
FC-AL diagnostics
FDDI diagnostics
Gigabit diagnostics
NVRAM diagnostics
RMC diagnostics
SCSI diagnostics
Floppy drive diagnostics
CompactFlash card diagnostics
Stress diagnostics
Error Messages
Error message coding conventions
DAH0001 through DAH0387
DAS0014 through DAS0015
DAU0004
DBH0301 through DBH0501
DBS0307
DEH0001 through DEH0216
DES0007 through DES0022
DFH0001 through DFH0032
DGH0001 through DGH0285
DGS0006
DHH0001
DLH0001 through DLH0100
DMH0001 through DMH0352
DMS0060 through DMS0061
DNH0101 through DNH0550
DNU0002 through DNU0106
DOH0001 through DOH0012
DPH0001 through DPH0029
DRH0001 through DRH0012
DRS0010
DRU0009
DSH0001 through DSH1015
DTH0001 through DTH0053
DTS0002, DTS0003, and DTS0010
DUH0002 through DUH0224
DUS0001
DZH0101 through DZH2002
DZS0430
Environmental Error Messages
C1200 environmental error codes
C2100 environmental error codes
F85 environmental error codes
F87 environmental error codes
F810 environmental error codes
F820/C3100 environmental error codes
F825 environmental error codes
F840/C6100 environmental error codes
F880 environmental error codes
FAS940 environmental error codes
FAS960 environmental error codes
R100 environmental error codes
R150 environmental error codes

DLH0001 through DLH0100

Message type

This error message grouping covers hardware errors associated with Fibre Channel cards that are in the filer. The corrective action for this error message grouping is below the error message description.

Error message description

The following messages can be generated for this message group.

Error code Sample message Description

DLH0001

Could not reset ISP on adapter ASCII_value

Card failed to reset the chip.

DLH0003

Mailbox timeout

Card failed to finish the given mailbox command.

DLH0004

Mailbox command returned with a failure note

During execution of the mailbox command, the value put on the incoming mailbox does not match the value that was received in the outgoing mailbox.

DLH0005

ISP VID is hex_value but should be hex_value

Card has an unrecognized vendor ID (not ISP2100 or ISP2200).

DLH0006

ISP DID is hex_value but should be either hex_value or hex_value

Card has an unrecognized device ID (not ISP2100 or ISP2200).

DLH0007

RISC status was hex_value, but should be hex_value

After reset, the card does not come back alive.

DLH0009

ISP firmware simple command

Card failed to execute a simple command (NOP operation).

DLH0010

ISP firmware bad command test

Card failed to execute an invalid command.

DLH0011

ISP firmware wraparound failed

Card failed to execute a wraparound mailbox command.

DLH0012

ISP firmware wraparound

The data transmitted to and received by the mailbox does not match.

DLH0013

Expected dec_value ISP2100 controllers, but only found 1

Card received an unexpected number of ISP chips.

DLH0014

Copy to SSRAM on channel dec_value failed

Card failed to write to Synchronous Static Random Access Memory (SSRAM).

DLH0015

Read from SSRAM on channel dec_value failed

Card failed to read from SSRAM.

DLH0016

Data mismatch at SSRAM word dec_value, channel dec_value, 
read hex_value, expected hex_value, dest hex_value, source hex_value

Read and written data do not match.

Note
The word is the address offset from the starting address in the word.

DLH0019

RISC checksum failed

Card failed when verifying the checksum of the downloaded firmware code.

DLH0020

FCAL loop is open, channel dec_value

Card failed to reconnect to the loop.

Check the cable, disk, and terminator plug.

DLH0021

Could not save new ISP 2100 settings to EEPROM; giving up after 2 retries

Card failed to download the EEPROM.

DLH0023

Unable to execute firmware: error code 0004

Card failed to execute the downloaded firmware.

DLH0025

FCAL loop is open, channel dec_value

Card failed to reconnect to the loop.

Check the cable, disk, and terminator plug.

DLH0026

No FCAL in slot dec_value

No card was found in designated slot.

DLH0030

isp2100_diag_reset_isp: while resetting ISP, ISP never came ready on adapter dec_value

Card failed to come back after reset.

DLH0032

FCAL ISP POST test failed: error code dec_value, count dec_value failing FIFO: hex_value, FIFO addr: hex_value

Card failed to execute the POST code given by the FC-AL vendor.

DLH0033

NOP command failed execution

Card failed to execute the NOP command.

DLH0034

Unexpected number of ISP 2100s; found dec_value

Chip number is incorrect.

DLH0035

The HCCR_INTR bit was not reset

Test failed to flush the previous command.

DLH0036

FCAL interrupt test failed, the interrupt test never got set

Card/test failed to set the interrupt bit to the main CPU.

DLH0037

FCAL interrupt bit either never got reset or it regenerated an interrupt

Test either failed to flush the previous command or the interrupt bit was reset.

DLH0038

There is a link failure or loss of sync or invalid CRC

System failed to receive the link status from the Fibre Channel chip.

DLH0039

FCTEST confidence factor is < 95

The fctest has a confidence factor of < 95%.

DLH0040

ISP internal loop test 10 bit failed during mail, channel dec_value

Applies to ISP2200 card only: Card failed to execute the internal loop test (before the serial transceiver).

DLH0041

ISP internal loop test 1 bit failed during mail, channel dec_value

DLH0042

ISP external loop test failed during mail, channel dec_value

Applies to ISP2200 card only: Card failed to execute the external loop test.

DLH0043

Data mismatch doing dec_value at word dec_value, channel dec_value, received hex_value, send hex_value

Card has a data mismatch when executing an internal or external loop test.

DLH0044

ISP failed to get device link status at channel dec_value, device # dec_value

Card failed to get device link status before the fctest.

DLH0045

ISP failed to get adapter link status at channel dec_value

Card failed to get adapter link status before the fctest.

DLH0046

ISP failed to execute fctest at channel dec_value

Card failed to execute the fctest.

DLH0047

ISP failed to get device link status at channel dec_value, device # dec_value

Card failed to get device link status after the fctest.

DLH0070

Unrecognized signature

The save EEPROM data has an invalid signature.

DLH0071

Invalid NVRAM minimum version

The save EEPROM data has an invalid NVRAM version.

DLH0072

EEPROM data checksum error

The save EEPROM data has an invalid checksum.

DLH0073

Serial number in EEPROM is not equal to the one in FLASH

Serial numbers saved in EEPROM and in FLASH do not match.

DLH0074

Never saw LIP occur after executing internal loopback test

Card never saw the loop initialization process (LIP) back up after executing the internal loopback test.

DLH0100

LED test failed

LED test failed.

Corrective action  Top

The following table lists the error message groupings and corrective action that can be taken for the error message group.

Error message group Corrective action

DLH0001-DLH0007
DLH0009-DLH0016
DLH0019, DLH0021
DLH0023
DLH0026-DLH0030
DLH0032-DLH0041
DLH0070-DLH0074
DLH0100

Replace the FC-AL card or contact Network Appliance Technical Support.

DLH0020, DLH0025
DLH0042-DLH0043

  1. Check the external connection.
  2. If the FC-AL card still fails, replace the card or contact Network Appliance Technical Support.

DLH0044-DLH0047

  1. Check the external connection, disk, and disk shelf.
  2. If the FC-AL card still fails, replace the card or contact Network Appliance Technical Support.