Legal Information |
DGH0001 through DGH0285
|
| Error code | Sample message | Description |
|---|---|---|
The control register offset is out of bounds |
Outbound message register does not have the correct value. |
|
Failed to set up command queue |
Failed to allocate memory and initialize the command queue. |
|
Failed to set up interrupt queue |
Failed to allocate memory and initialize the interrupt queue. |
|
Failed to reset NIC |
Failed to reset the card. |
|
NIC in wrong state |
After reset, the card is not in standby state. |
|
Queue not found |
Return interrupt queue is empty. |
|
Interrupt bit not set |
Card did not set the interrupt bit after executing the command, and timed out. |
|
Invalid parameter |
Return error status from the card. | |
Invalid state | ||
Resource error | ||
EEPROM checksum mismatch |
Read and expected checksum do not match. | |
Invalid command |
Return error code from card. | |
Unknown error hex_value | ||
Reply message expected |
Host was expecting a reply message, but did not get it. | |
Notify message expected |
Host was expecting a notify message, but did not get it. | |
Loopback start failure |
Return error code from card during loopback test and DMA test. | |
Set loopback failure | ||
Allocate packet failure | ||
Data mismatch | ||
Packet not received | ||
Reset loopback failure | ||
Link could not be established | ||
Loopback packet not sent | ||
DMA test fail | ||
Could not get the interrupt |
Host was waiting for interrupt, but timed out. | |
Card failed to reboot |
Card failed to reboot during warm reset. | |
DRAM data bus failure |
Return error code from card during warm reset. | |
DRAM address bus stuck high failure | ||
DRAM address bus stuck low failure | ||
DRAM address bus shorted failure | ||
Memory test report device failure | ||
Flash checksum mismatch | ||
Could not initialize the registers |
Failed to initialize device registers. | |
Flash manufacture ID and device ID do not match |
Read out manufacture ID and device ID of the flash are not what was expected. | |
8M PCI memory, i960 switches 1 & 2 must be on |
Unless 16M is mapped in, switches 1 and 2 are not set to On. | |
hex_value PCI memory should be 16M |
16M should be mapped in. |
The following table lists the error message groupings and corrective action that can be taken for the error message group.
| Error message group | Corrective action |
|---|---|
Replace the GbE card or contact Network Appliance Technical Support. |
|
|