DMH0001 through DMH0352
Message type
This error message grouping covers hardware errors associated with the storage
appliance
onboard memory.
When the memory diagnostics encounter errors, or if recoverable ECC errors occur, the diagnostics
attempt to analyze the error and identify the failing DIMMs.
Bank part numbers are silk-screened on the motherboard, adjacent to the SIMM sockets.
Example
When an error is encountered, the diagnostics display an error message similar to the following:
ERROR: Addr=04b1329e: Exp=55aa55aa, Act=55af55aa, Diff=00050000
** DIMM banks indicating errors: U101
** Cache SRAMs indicating errors: E44
Error message description
The following messages can be generated for this message group.
| Error code |
Sample message |
Description |
DMH0001-DMH0059 |
Addr=hex_value: Exp=hex_value, Act=hex_value, Diff=hex_value
** SIMM banks indicating errors: hex_value |
Data might be corrupted and a specific DIMM is bad. Read/write error. |
DMH0101-DMH0106
DMH0301-DMH0352 |
Addr=hex_value Exp=hex_value, Act=hex_value, Diff=hex_value |
An error in cache memory is found and identified. Cache errors require replacement of the motherboard. |
Corrective action for DMH0001 through DMH0352
The following table lists the error message groupings and corrective action that can be taken for the error message group.
| Error message group |
Corrective action |
DMH0001-DMH0059 |
Replace the DIMM/SIMM for DIMM/SIMM errors. Call Network Appliance Technical Support for cache errors. |
DMH0101-DMH0352 |
- Replace the motherboard
- Call Network Appliance Technical Support if
the error is not corrected.
|
|