This error message grouping covers hardware errors associated with the SCSI cards in the filer.
The corrective action for this error message grouping is below the error message description.
The following messages can be generated for this message group.
| Error code |
Sample message |
Description |
DSH0001 |
Not a NetApp Dual SCSI card; bridge test skipped |
SCSI card found is not a NetApp Dual SCSI card. |
DSH0002 |
PLX VID is hex_value but should be hex_value or hex_value |
Test found the wrong PLX VID. |
DSH0003 |
PLX DID is hex_value but should be hex_value, hex_value, hex_value |
Test found an unexpected PLX DID. |
DSH0004 |
PLX revision is hex_value; illegal dec_value |
Revision found is illegal. |
DSH0005 |
Base class is hex_value but should be hex_value |
Test found an incorrect SCSI base class. |
DSH0006 |
SubClass is hex_value but should be hex_value |
Test found an incorrect subclass. |
DSH0007 |
Interrupt pin is hex_value but should be hex_value |
Test found an incorrect interrupt pin on the SCSI cable. |
DSH0008 |
PLX selftest failed |
Test failed to run the PLX self test. |
DSH0009 |
EEPROM data error |
Test found an invalid EEPROM value in one of the bits. |
DSH0010 |
Could not reset ISP |
SCSI adapter cannot reset itself. |
DSH0011 |
ISP VID is hex_value but should be hex_value |
Test found the wrong SCSI VID. |
DSH0012 |
ISP DID is hex_value but should be hex_value or hex_value |
Test found the wrong SCSI DID. |
DSH0013 |
ISP revision is hex_value; illegal dec_value |
Test found the wrong SCSI revision. |
DSH0014 |
RISC status was hex_value but should be hex_value |
SCSI adapter never came back alive. |
DSH0015 |
MBOX register 1 was hex_value but should be hex_value |
SCSI adapter returned a different product ID word. |
DSH0016 |
ISP firmware simple command test failed |
SCSI adapter failed to execute NOP operation. |
DSH0017 |
ISP firmware bad command test failed |
Invalid command entered; the SCSI adapter responds with invalid return status. |
DSH0018 |
ISP firmware wraparound failed |
SCSI adapter failed to execute the wraparound mailbox command. |
DSH0019 |
ISP firmware wraparound mailbox # dec_value: read hex_value, expected hex_value |
During execution of the wraparound mailbox command, the value put on the incoming mailbox does not match the value that was received in the outgoing mailbox. |
DSH0020 |
Expected dec_value ISP controllers, but found dec_value |
Number of ISP chips found does not match the number recorded. |
DSH0021 |
Copy to SSRAM on slot dec_value failed |
SCSI adapter failed to copy DMA data to the SSRAM. |
DSH0022 |
Read from SSRAM on slot dec_value failed |
SCSI failed to read DMA data to the host. |
DSH0023 |
Data mismatch at SSRAM word # dec_value, slot dec_value, read hex_value, expected hex_value, dest hex_value, source hex_value |
Value read from SSRAM does not match the value written to SSRAM. |
DSH0024 |
Read of firmware from SSRAM failed |
SCSI adapter failed to dump the firmware value written to the host. |
DSH0025 |
Firmware data mismatch at word # dec_value, read hex_value, expected hex_value |
Firmware data written to SSRAM does not match the firmware data that was read from SSRAM. |
DSH0026 |
Firmware checksum failed |
SCSI adapter failed the firmware checksum. |
DSH0027 |
The HCCR_INTR bit was not reset |
HCCR interrupt bit has not cleared existing data. |
DSH0028 |
SCSI interrupt test failed, the interrupt test never got set |
SCSI adapter interrupt is not set. |
DSH0029 |
SCSI interrupt bit either never got reset or it regenerated |
SCSI adapter interrupt is not set or the interrupt
was set again. |
DSH0030 |
Unable to execute firmware: error code hex_value |
SCSI adapter failed to execute the loaded firmware. |
DSH0031 |
Expected vendor hex_value, device dec_value saw vendor hex_value, device dec_value |
Vendor ID numbers on the device and in the device database do not match. |
DSH0032 |
No SCSI in slot dec_value |
Cannot find SCSI adapter in the specified slot. |
DSH0033 |
Copy of firmware to SSRAM failed |
SCSI adapter failed to copy the firmware to SSRAM. |
DSH0034 |
Copy of stress Qlogic code to SSRAM failed |
SCSI adapter failed to copy the Qlogic stress code to SSRAM. |
DSH0035 |
Qlogic stress code checksum failed |
SCSI adapter failed when doing a checksum for a given Qlogic stress code. |
DSH0036 |
Unable to execute Qlogic stress code |
Cannot execute Qlogic stress code. |
DSH0037 |
Read from SSRAM on slot dec_value failed |
SCSI device failed to read the SSRAM in the identified slot. |
DSH0038 |
Read from firmware from SSRAM in slot dec_value failed |
SCSI device failed to read the SSRAM in the identified slot during the firmware test. |
DSH0039 |
Failed to reset adapter card |
Failed to reset SCSI adapter card. |
DSH0040 |
Failed to reset ISP |
Failed to reset SCSI chip. |
DSH0041 |
Data mismatch at SSRAM word hex_value, slot dec_value, read hex_value, expected hex_value |
Value read from SSRAM does not match the value written to SSRAM. |
DSH0042 |
Firmware data mismatch at word dec_value, read hex_value, expected hex_value |
Firmware data written to SSRAM does not match the firmware data that was read from SSRAM. |
DSH0050 |
Failed to flush previous pending mailbox command |
SCSI adapter failed to flush the previous pending mailbox command. |
DSH0051 |
Mailbox command failed to finish |
SCSI adapter found a timeout when executing a mailbox command. |
DSH1000 |
SCSI adapter in slot dec_value, port dec_value is dead |
Adapter is marked dead. |
DSH1001 |
SCSI adapter in slot dec_value, port dec_value is currently in OSM event mode |
Adapter is busy executing the OSM event and cannot be disturbed. |
DSH1002 |
Failed to initialize SCSI adapter in slot dec_value, port dec_value |
Adapter failed to do hardware initialization. |
DSH1003 |
Timeout when initializing SCSI adapter in slot dec_value, port dec_value |
A timeout occurred during the hardware initialization. |
DSH1004 |
Failed to reset SCSI adapter in slot dec_value, port dec_value |
Resetting of the SCSI adapter failed. |
DSH1005 |
Timeout when resetting SCSI adapter in slot dec_value, port dec_value |
A timeout occurred while the SCSI adapter was being reset. |
DSH1006 |
Failed to reset SCSI adapter bus in slot dec_value, port dec_value |
Adapter failed to do a bus reset. |
DSH1007 |
Timeout when resetting SCSI adapter bus in slot dec_value, port dec_value |
A timeout occurred while the adapter bus was being reset. |
DSH1008 |
Failed to reset target in slot dec_value, port dec_value |
Adapter failed to do specific disk reset. |
DSH1009 |
Timeout when resetting target in slot dec_value, port dec_value |
A timeout occurred while a specific disk was being reset. |
DSH1010 |
Failed to rescan SCSI adapter in slot dec_value, port dec_value |
Adapter failed to do a rescan. |
DSH1011 |
Timeout when rescanning SCSI adapter in slot dec_value, port dec_value |
A timeout occurred during rescanning. |
DSH1012 |
Timeout from SCSI during disk init in slot dec_value, port dec_value |
A timeout occurred during disk initialization through this adapter. |
DSH1013 |
OSM event happened for SCSI card in slot dec_value, port dec_value and failed to handle it |
An OSM event happened during the task and the adapter failed to handle it. |
DSH1014 |
ISP VID is 0x%x but should be 0x%x |
Wrong vendor ID. |
DSH1015 |
ISP DID is 0x%x but should be 0x%x |
Wrong device ID. |
The following table lists the error message groupings and corrective action that can be taken for the error message group.