images/nav1.gif (4223 bytes)

Legal Information
Copyright
Trademarks
Support note
Communications regulations
Contact Information
Preface
Safety Information
Overview of the Diagnostics Guide
About diagnostics
Optional materials
Booting the diagnostics program
Booting from FLASH
Booting from CompactFlash
Booting from a diskette
Running Diagnostics
Diagnostic Monitor user interface
Diagnostics menu options
Commands menu options
Options menu options
Running diagnostic tests
Running all diagnostic tests
Running individual diagnostic tests
Test results
Diagnostics Menus
Motherboard diagnostics
C1200 motherboard tests
C2100 motherboard tests
F85 motherboard tests
F87 motherboard tests
F800 series/C3100/C6100/R100 motherboard tests
FAS900 series/R150 motherboard tests
Main memory diagnostics
Card diagnostics
ATM diagnostics
DAFS diagnostics
Cluster interconnect diagnostics
Ethernet diagnostics
FC-AL diagnostics
FDDI diagnostics
Gigabit diagnostics
NVRAM diagnostics
RMC diagnostics
SCSI diagnostics
Floppy drive diagnostics
CompactFlash card diagnostics
Stress diagnostics
Error Messages
Error message coding conventions
DAH0001 through DAH0387
DAS0014 through DAS0015
DAU0004
DBH0301 through DBH0501
DBS0307
DEH0001 through DEH0216
DES0007 through DES0022
DFH0001 through DFH0032
DGH0001 through DGH0285
DGS0006
DHH0001
DLH0001 through DLH0100
DMH0001 through DMH0352
DMS0060 through DMS0061
DNH0101 through DNH0550
DNU0002 through DNU0106
DOH0001 through DOH0012
DPH0001 through DPH0029
DRH0001 through DRH0012
DRS0010
DRU0009
DSH0001 through DSH1015
DTH0001 through DTH0053
DTS0002, DTS0003, and DTS0010
DUH0002 through DUH0224
DUS0001
DZH0101 through DZH2002
DZS0430
Environmental Error Messages
C1200 environmental error codes
C2100 environmental error codes
F85 environmental error codes
F87 environmental error codes
F810 environmental error codes
F820/C3100 environmental error codes
F825 environmental error codes
F840/C6100 environmental error codes
F880 environmental error codes
FAS940 environmental error codes
FAS960 environmental error codes
R100 environmental error codes
R150 environmental error codes

DSH0001 through DSH1015

Message type

This error message grouping covers hardware errors associated with the SCSI cards in the filer. The corrective action for this error message grouping is below the error message description.

Error message description

The following messages can be generated for this message group.

Error code Sample message Description

DSH0001

Not a NetApp Dual SCSI card; bridge test skipped

SCSI card found is not a NetApp Dual SCSI card.

DSH0002

PLX VID is hex_value but should be hex_value or hex_value

Test found the wrong PLX VID.

DSH0003

PLX DID is hex_value but should be hex_value, hex_value, hex_value

Test found an unexpected PLX DID.

DSH0004

PLX revision is hex_value; illegal dec_value

Revision found is illegal.

DSH0005

Base class is hex_value but should be hex_value

Test found an incorrect SCSI base class.

DSH0006

SubClass is hex_value but should be hex_value

Test found an incorrect subclass.

DSH0007

Interrupt pin is hex_value but should be hex_value

Test found an incorrect interrupt pin on the SCSI cable.

DSH0008

PLX selftest failed

Test failed to run the PLX self test.

DSH0009

EEPROM data error

Test found an invalid EEPROM value in one of the bits.

DSH0010

Could not reset ISP

SCSI adapter cannot reset itself.

DSH0011

ISP VID is hex_value but should be hex_value

Test found the wrong SCSI VID.

DSH0012

ISP DID is hex_value but should be hex_value or hex_value

Test found the wrong SCSI DID.

DSH0013

ISP revision is hex_value; illegal dec_value

Test found the wrong SCSI revision.

DSH0014

RISC status was hex_value but should be hex_value

SCSI adapter never came back alive.

DSH0015

MBOX register 1 was hex_value but should be hex_value

SCSI adapter returned a different product ID word.

DSH0016

ISP firmware simple command test failed

SCSI adapter failed to execute NOP operation.

DSH0017

ISP firmware bad command test failed

Invalid command entered; the SCSI adapter responds with invalid return status.

DSH0018

ISP firmware wraparound failed

SCSI adapter failed to execute the wraparound mailbox command.

DSH0019

ISP firmware wraparound mailbox # dec_value: read hex_value, expected hex_value

During execution of the wraparound mailbox command, the value put on the incoming mailbox does not match the value that was received in the outgoing mailbox.

DSH0020

Expected dec_value ISP controllers, but found dec_value

Number of ISP chips found does not match the number recorded.

DSH0021

Copy to SSRAM on slot dec_value failed

SCSI adapter failed to copy DMA data to the SSRAM.

DSH0022

Read from SSRAM on slot dec_value failed

SCSI failed to read DMA data to the host.

DSH0023

Data mismatch at SSRAM word # dec_value, slot dec_value, read hex_value, expected hex_value, dest hex_value, source hex_value

Value read from SSRAM does not match the value written to SSRAM.

DSH0024

Read of firmware from SSRAM failed

SCSI adapter failed to dump the firmware value written to the host.

DSH0025

Firmware data mismatch at word # dec_value, read hex_value, expected hex_value

Firmware data written to SSRAM does not match the firmware data that was read from SSRAM.

DSH0026

Firmware checksum failed

SCSI adapter failed the firmware checksum.

DSH0027

The HCCR_INTR bit was not reset

HCCR interrupt bit has not cleared existing data.

DSH0028

SCSI interrupt test failed, the interrupt test never got set

SCSI adapter interrupt is not set.

DSH0029

SCSI interrupt bit either never got reset or it regenerated

SCSI adapter interrupt is not set or the interrupt was set again.

DSH0030

Unable to execute firmware: error code hex_value

SCSI adapter failed to execute the loaded firmware.

DSH0031

Expected vendor hex_value, device dec_value saw vendor hex_value, device dec_value

Vendor ID numbers on the device and in the device database do not match.

DSH0032

No SCSI in slot dec_value

Cannot find SCSI adapter in the specified slot.

DSH0033

Copy of firmware to SSRAM failed

SCSI adapter failed to copy the firmware to SSRAM.

DSH0034

Copy of stress Qlogic code to SSRAM failed

SCSI adapter failed to copy the Qlogic stress code to SSRAM.

DSH0035

Qlogic stress code checksum failed

SCSI adapter failed when doing a checksum for a given Qlogic stress code.

DSH0036

Unable to execute Qlogic stress code

Cannot execute Qlogic stress code.

DSH0037

Read from SSRAM on slot dec_value failed

SCSI device failed to read the SSRAM in the identified slot.

DSH0038

Read from firmware from SSRAM in slot dec_value failed

SCSI device failed to read the SSRAM in the identified slot during the firmware test.

DSH0039

Failed to reset adapter card

Failed to reset SCSI adapter card.

DSH0040

Failed to reset ISP

Failed to reset SCSI chip.

DSH0041

Data mismatch at SSRAM word hex_value, slot dec_value, read hex_value, expected hex_value

Value read from SSRAM does not match the value written to SSRAM.

DSH0042

Firmware data mismatch at word dec_value, read hex_value, expected hex_value

Firmware data written to SSRAM does not match the firmware data that was read from SSRAM.

DSH0050

Failed to flush previous pending mailbox command

SCSI adapter failed to flush the previous pending mailbox command.

DSH0051

Mailbox command failed to finish

SCSI adapter found a timeout when executing a mailbox command.

DSH1000

SCSI adapter in slot dec_value, port dec_value is dead

Adapter is marked dead.

DSH1001

SCSI adapter in slot dec_value, port dec_value is currently in OSM event mode

Adapter is busy executing the OSM event and cannot be disturbed.

DSH1002

Failed to initialize SCSI adapter in slot dec_value, port dec_value

Adapter failed to do hardware initialization.

DSH1003

Timeout when initializing SCSI adapter in slot dec_value, port dec_value

A timeout occurred during the hardware initialization.

DSH1004

Failed to reset SCSI adapter in slot dec_value, port dec_value

Resetting of the SCSI adapter failed.

DSH1005

Timeout when resetting SCSI adapter in slot dec_value, port dec_value

A timeout occurred while the SCSI adapter was being reset.

DSH1006

Failed to reset SCSI adapter bus in slot dec_value, port dec_value

Adapter failed to do a bus reset.

DSH1007

Timeout when resetting SCSI adapter bus in slot dec_value, port dec_value

A timeout occurred while the adapter bus was being reset.

DSH1008

Failed to reset target in slot dec_value, port dec_value

Adapter failed to do specific disk reset.

DSH1009

Timeout when resetting target in slot dec_value, port dec_value

A timeout occurred while a specific disk was being reset.

DSH1010

Failed to rescan SCSI adapter in slot dec_value, port dec_value

Adapter failed to do a rescan.

DSH1011

Timeout when rescanning SCSI adapter in slot dec_value, port dec_value

A timeout occurred during rescanning.

DSH1012

Timeout from SCSI during disk init in slot dec_value, port dec_value

A timeout occurred during disk initialization through this adapter.

DSH1013

OSM event happened for SCSI card in slot dec_value, port dec_value and failed to handle it

An OSM event happened during the task and the adapter failed to handle it.

DSH1014

ISP VID is 0x%x but should be 0x%x

Wrong vendor ID.

DSH1015

ISP DID is 0x%x but should be 0x%x

Wrong device ID.

Corrective action

The following table lists the error message groupings and corrective action that can be taken for the error message group.

Error message group Corrective action

DSH0001-DSH0038
DSH0040-DSH0051
DSH1000-DSH1007
DSH1013-DSH1015

Replace the SCSI card or contact Network Appliance Technical Support.

DSH0039

  1. Check that the external loopback plug is connected.
  2. If it is connected, and the SCSI card still fails, call Network Appliance Technical Support.

DSH1008

Replace the bad disk. Call Network Appliance Technical Support.

DSH1009-DSH1012

  1. Replace the bad disk.

  2. Replace the SCSI card.
  3. Call Network Appliance Technical Support.