F87 environmental error codes
|
| Platform and sensor code | Sensor description |
|---|---|
ENV00360x |
CPU0. |
ENV00361x |
Motherboard planar. |
ENV00406x |
Backplane_top (bp_ top). |
ENV00407x |
Backplane_bottom (bp_ bottom). |
ENV00412x |
Secondary backplane_top (sbp_ top). |
The following table lists the error messages that can be generated by the temperature sensors on the motherboard and the SCSI backplane card. The corrective action for these error messages is below the error message description.
Note: "[d]" in the sample error message represents one of the five temperature sensors.
| If "x" is... | Sample error message | Description |
|---|---|---|
1 |
[d] does not read | Cannot read [d] temperature sensor. |
2 |
[d] is in critical high state | [d] temperature sensor exceeds critical high threshold. |
3 |
[d] is in warning high state | [d] temperature exceeds warning high threshold. |
4 |
[d] is in warning low state | [d] temperature falls below warning low threshold. |
5 |
[d] is in critical low state |
[d] temperature falls below critical low threshold. |
6 |
[d] expected high interrupt did not occur |
Missing interrupt when the [d] temperature exceeds warning high threshold. |
7 |
[d] expected low interrupt did not occur |
Missing interrupt when the [d] temperature falls below warning low threshold. |
The following table lists the corrective action that can be taken for error messages generated by the temperature sensors.
| Error message | Corrective action |
|---|---|
ENV003601-ENV003607, |
|
ENV004061-ENV004067, |
|
ENV004121-ENV004127 |
|