F880 environmental error codes
Chassis and CPU fan sensors
Chassis and CPU fan sensor error message description
Error messages can be generated by the following chassis and CPU fan
sensors.
Note: The "x" in the code represents the actual error
condition.
| Platform and sensor code |
Sensor description |
ENV00266x |
Backplane fan #1 (Backplane_Fan_1). |
ENV00267x |
Backplane fan #2 (Backplane_Fan_2). |
ENV00264x |
Backplane fan #3 (Backplane_Fan_3). |
ENV00265x |
Backplane fan #4 (Backplane_Fan_4). |
ENV00262x |
Backplane fan #5 (Backplane_Fan_5). |
ENV00263x |
Backplane fan #6 (Backplane_Fan_6). |
The following table lists the error messages that can be generated by the
chassis and CPU fan sensors. The corrective
action for this error message grouping is below the error message
description.
Note: "[d]" in the sample error message represents one of the six backplane fan sensors or the CPU fan sensor.
| If "x" is... |
Sample error message |
Description |
1 |
[d] does not read |
Cannot read [d] sensor. |
2 |
[d] is in critical high state |
[d] speed read exceeds critical high threshold. |
3 |
[d] is in warning high state |
[d] speed read exceeds warning high threshold. |
4 |
[d] is in warning low state |
[d] speed read exceeds warning low threshold. |
5 |
[d] is in critical low state |
[d] speed read exceeds critical low threshold. |
6 |
[d] expected high interrupt did not occur |
Missing interrupt when the [d] speed exceeds warning high threshold. |
7 |
[d] expected low interrupt did not occur |
Missing interrupt when the [d] speed exceeds warning low threshold. |
Replace the fans.
|