FAS940 environmental error codes
|
| Platform and sensor code | Sensor description |
|---|---|
ENV00641x |
Hotswap Fan 1. |
ENV00642x |
Hotswap Fan 2. |
ENV00643x |
Hotswap Fan 3. |
The following table lists the error messages that can be generated by the fan module sensors.
Note: "[d]" in the sample error message represents one of the three fan module sensors.
| If "x" is... | Sample error message | Description |
|---|---|---|
1 |
[d] does not read | [d] module is not responding. |
2 |
[d] is in bad state | [d] module is missing. |
Status error messages can be generated by the following baseboard fans within each fan module and the power supply fans within each power supply module.
Note: The "x" in the code represents the actual error condition.
| Platform and sensor code | Sensor description |
|---|---|
ENV00644x |
Baseboard Fan 1. |
ENV00645x |
Baseboard Fan 2. |
ENV00646x |
Baseboard Fan 3. |
ENV00647x |
Baseboard Fan 4. |
ENV00648x |
Baseboard Fan 5. |
ENV00649x |
Baseboard Fan 6. |
ENV00670x |
PS Fan 1 (Power supply fan 1). |
ENV00671x |
PS Fan 2 (Power supply fan 2). |
ENV00672x |
PS Fan 3 (Power supply fan 3). |
ENV00673x |
PS Fan 4 (Power supply fan 4). |
The following table lists the error messages that can be generated by the baseboard and power supply fan sensors.
Note: "[d]" in the sample error message represents one of the six baseboard fan sensors or one of the four power supply fan sensors.
| If "x" is... | Sample error message | Description |
|---|---|---|
1 |
[d] does not read | Cannot read [d] sensor. |
2 |
[d] is in critical high state | [d] speed read exceeds critical high threshold. |
3 |
[d] is in warning high state | [d] speed read exceeds warning high threshold. |
4 |
[d] is in warning low state | [d] speed read exceeds warning low threshold. |
5 |
[d] is in critical low state |
[d] speed read exceeds critical low threshold. |
6 |
[d] expected high interrupt did not occur |
Missing interrupt when the [d] speed exceeds warning high threshold. |
7 |
[d] expected low interrupt did not occur |
Missing interrupt when the [d] speed exceeds warning low threshold. |
8 |
[d] can’t be speeded up | [d] cannot be speeded up by the system. |
9 |
[d] can’t be slowed down |
[d] cannot be slowed down by the system. |
Replace the fans.