Legal Information |
FAS940 environmental error codes
|
| Platform and sensor code | Sensor description |
|---|---|
ENV00634x |
CIOB +2.5 Volt. |
ENV00635x |
Baseboard 3.3 Volt. |
ENV00636x |
3.3 Volt Standby. |
ENV00637x |
Baseboard 5.0 Volt. |
ENV00638x |
Baseboard +12 Volt. |
ENV00639x |
Baseboard -12 Volt. |
| ENV00640x | Processor VCCP |
ENV00650x |
Real time clock battery (RTC_batt). |
ENV00652x |
CMIC +2.5 Volt. |
ENV00653x |
CCSB5 +2.5 Volt. |
ENV00654x |
MemoryBrd +2.5 Volt (Memory board 2.5 Volt). |
ENV00655x |
MB 5.0 Volt Standby (Memory board 5.0 Volt standby). |
ENV00656x |
PS 1 3.3 Volt (power supply 1 3.3 Volt). |
ENV00657x |
PS 2 3.3 Volt (power supply 2 3.3 Volt). |
ENV00658x |
PS 1 5.0 Volt (power supply 1 5.0 Volt). |
ENV00659x |
PS 2 5.0 Volt (power supply 2 5.0 Volt). |
ENV00660x |
PS 1 12 Volt (power supply 1 12 Volt). |
ENV00661x |
PS 2 12 Volt (power supply 2 12 Volt). |
ENV00662x |
PS 1 AC (power supply 1 alternating current). |
ENV00663x |
PS 2 AC (power supply 2 alternating current). |
ENV00664x |
PS 1 Crnt 3.3 Volt (power supply 1 3.3 Volt). |
ENV00665x |
PS 2 Crnt 3.3 Volt (power supply 2 3.3 Volt). |
ENV00666x |
PS 1 Crnt 5.0 Volt (power supply 1 5.0 Volt). |
ENV00667x |
PS 2 Crnt 5.0 Volt (power supply 2 5.0 Volt). |
ENV00668x |
PS 1 Crnt 12 Volt (power supply 1 12 Volt). |
ENV00669x |
PS 2 Crnt 12 Volt (power supply 2 12 Volt). |
The following table lists the error messages that can be generated by the voltage power sensors. The corrective action for these error messages is below the error message description.
Note: "[d]" in the sample error message represents one of the seven voltage power sensors.
| If "x" is... | Sample error message | Description |
|---|---|---|
1 |
[d] does not read | Cannot read [d] power sensor. |
2 |
[d] is in critical high state | [d] power sensor exceeds critical high threshold. |
3 |
[d] is in warning high state | [d] power exceeds warning high threshold. |
4 |
[d] is in warning low state | [d] power falls below warning low threshold. |
5 |
[d] is in critical low state |
[d] power falls below critical low threshold. |
6 |
[d] expected high interrupt did not occur |
Missing interrupt when the [d] power exceeds warning high threshold. |
7 |
[d] expected low interrupt did not occur |
Missing interrupt when the [d] power falls below warning low threshold. |
The following table lists the corrective action that can be taken for error messages generated by the voltage power and battery sensors.
| Error message | Corrective action |
|---|---|
ENV00650x |
|
ENV00634x-ENV00640x |
|