images/nav1.gif (4223 bytes)

Legal Information
Copyright
Trademarks
Support note
Communications regulations
Contact Information
Preface
Safety Information
Overview of the Diagnostics Guide
About diagnostics
Optional materials
Booting the diagnostics program
Booting from FLASH
Booting from CompactFlash
Booting from a diskette
Running Diagnostics
Diagnostic Monitor user interface
Diagnostics menu options
Commands menu options
Options menu options
Running diagnostic tests
Running all diagnostic tests
Running individual diagnostic tests
Test results
Diagnostics Menus
Motherboard diagnostics
C1200 motherboard tests
C2100 motherboard tests
F85 motherboard tests
F87 motherboard tests
F800 series/C3100/C6100/R100 motherboard tests
FAS900 series/R150 motherboard tests
Main memory diagnostics
Card diagnostics
ATM diagnostics
DAFS diagnostics
Cluster interconnect diagnostics
Ethernet diagnostics
FC-AL diagnostics
FDDI diagnostics
Gigabit diagnostics
NVRAM diagnostics
RMC diagnostics
SCSI diagnostics
Floppy drive diagnostics
CompactFlash card diagnostics
Stress diagnostics
Error Messages
Error message coding conventions
DAH0001 through DAH0387
DAS0014 through DAS0015
DAU0004
DBH0301 through DBH0501
DBS0307
DEH0001 through DEH0216
DES0007 through DES0022
DFH0001 through DFH0032
DGH0001 through DGH0285
DGS0006
DHH0001
DLH0001 through DLH0100
DMH0001 through DMH0352
DMS0060 through DMS0061
DNH0101 through DNH0550
DNU0002 through DNU0106
DOH0001 through DOH0012
DPH0001 through DPH0029
DRH0001 through DRH0012
DRS0010
DRU0009
DSH0001 through DSH1015
DTH0001 through DTH0053
DTS0010
DUH0002 through DUH0224
DUS0001
DZH0101 through DZH2002
DZS0430
Environmental Error Messages
C1200 environmental error codes
C2100 environmental error codes
F85 environmental error codes
F87 environmental error codes
F810 environmental error codes
F820/C3100 environmental error codes
F825 environmental error codes
F840/C6100 environmental error codes
F880 environmental error codes
FAS940 environmental error codes
FAS960 environmental error codes
R100 environmental error codes
R150 environmental error codes

FAS960 environmental error codes
Fan sensors

Fan sensor error message description

Error messages can be generated by the fan sensors for existence and status. The corrective action for all fan sensor error messages is below all the error message descriptions.

Fan sensors for existence

Error messages can be generated by the hotswap fan sensors to indicate the existence of the fan module within the chassis.

Note: The "x" in the code represents the actual error condition.

Platform and sensor code Sensor description

ENV00701x

Hotswap Fan 1.

ENV00702x

Hotswap Fan 2.

ENV00703x

Hotswap Fan 3.

The following table lists the error messages that can be generated by the fan module sensors.

Note: "[d]" in the sample error message represents one of the three fan module sensors.

If "x" is... Sample error message Description

1

[d] does not read

[d] module is not responding.

2

[d] is in bad state

[d] module is missing.

Fan sensors for status

Status error messages can be generated by the following baseboard fans within each fan module and the power supply fans within each power supply module.

Note: The "x" in the code represents the actual error condition.

Platform and sensor code Sensor description

ENV00704x

Baseboard Fan 1.

ENV00705x

Baseboard Fan 2.

ENV00706x

Baseboard Fan 3.

ENV00707x

Baseboard Fan 4.

ENV00708x

Baseboard Fan 5.

ENV00709x

Baseboard Fan 6.

ENV00730x

PS Fan 1 (Power supply fan 1).

ENV00731x

PS Fan 2 (Power supply fan 2).

ENV00732x

PS Fan 3 (Power supply fan 3).

ENV00733x

PS Fan 4 (Power supply fan 4).

The following table lists the error messages that can be generated by the baseboard and power supply fan sensors.

Note: "[d]" in the sample error message represents one of the six baseboard fan sensors or one of the four power supply fan sensors.

If "x" is... Sample error message Description

1

[d] does not read

Cannot read [d] sensor.

2

[d] is in critical high state

[d] speed read exceeds critical high threshold.

3

[d] is in warning high state

[d] speed read exceeds warning high threshold.

4

[d] is in warning low state

[d] speed read exceeds warning low threshold.

5

[d] is in critical low state

[d] speed read exceeds critical low threshold.

6

[d] expected high interrupt did not occur

Missing interrupt when the [d] speed exceeds warning high threshold.

7

[d] expected low interrupt did not occur

Missing interrupt when the [d] speed exceeds warning low threshold.

8

[d] can’t be speeded up

[d] cannot be speeded up by the system.

9

[d] can’t be slowed down

[d] cannot be slowed down by the system.

Corrective action