Cluster messages

LCD messages

Where cluster LCD messages appear  Top

LCD messages appear on two lines on the filer's LCD. Cluster messages, if they appear at all, appear on the first line of the LCD; other messages appear on the second line.

Cluster LCD messages that indicate trouble are accompanied by an amber LED indicator.

Cluster LCD messages  Top

The following messages pertaining to clusters can appear on the LCD of a takeover filer. These are messages that you can take steps to address.

Message

Explanation

What you do

cf disabled

Takeover has been disabled.

Follow these steps:

  1. Unless you want takeover to be disabled, issue the cf enable command.
  2. Check the interconnect cables to make sure that they are seated properly.
  3. Issue the cf status command to verify the link.
Giveback

The filer has given back and is waiting for the partner to boot.

Boot the partner.

Iconnect down!

The cluster interconnect link is broken.

Follow these steps:

  1. Check the cluster interconnect cables to make sure that they are seated properly.
  2. Issue the cf status command to verify the link.
Iconnect error

One of the cluster interconnect link cables is broken.

Follow these steps:

  1. Check the interconnect cables to make sure that they are functioning properly.
  2. Issue the cf status command to verify the link.
L: vol volume n% 
rebuilt

The filer has taken over its partner and one of its own volumes is reconstructing itself.

Wait until the message disappears.

P: vol volume n% 
rebuilt

The filer has taken over its partner and one of its partner's volumes is reconstructing itself.

Wait until the message disappears.

partner down

The partner is down and takeover is disabled.

If you want to take over the partner, issue the cf enable command, then the cf takeover command.

takeover

The filer has taken over its partner.

Perform a giveback.

takeover in nnn

The filer is counting down seconds until it takes over its partner.

Unless you want takeover to occur, issue the cf disable command.

Failed filer LCD message  Top

The following message pertaining to a cluster can appear on the LCD of a failed filer.

Message

Explanation

What you do

taken over

The filer has been taken over.

Follow these steps:

  1. Perform maintenance on the filer.
  2. Perform a giveback from the takeover filer.

Library Table of Contents Index Previous Next Comments