The checksum upgrade process is a long process that occurs when you upgrade Data ONTAP on your filer. The following is a brief description of how Data ONTAP upgrades the checksum.
The vol status -c command provides details about a block checksum upgrade.
The following example shows checksum status during the WAFL upgrade phase:
vol status -c
Volume Checksum status
vol0 Checksums initializing:
WAFL upgrade in progress
The following example shows snapshots that must be deleted before the WAFL upgrade can finish:
vol status -c
Volume Checksum status
vol0 Checksums initializing:
WAFL upgrade will complete when the following
snapshots are deleted:
date name
------------ ------------
Jan 21 18:00 snap.0
Sep 23 10:04 snap.2
The following example shows checksum status during RAID upgrade, phase one:
vol status -c
Volume Checksum status
vol0 Checksums initializing:
RAID upgrade phase 1 (of 2) in
progress (25% complete).
The following example shows checksum status during RAID upgrade, phase two:
vol status -c
Volume Checksum status
vol0 Checksums initializing:
RAID upgrade phase 2 (of 2) will be performed
during next disk scrub.
The following example shows a completed checksum upgrade:
vol status -c
Volume Checksum status
vol0 Checksums active:
Copyright © 1994-2003, Network Appliance, Inc. All rights
reserved.
Part No. 210-00322
File: stats7.htm
Last updated: 01/22/03 16:17:23