These error messages might appear on the system console when the system is operating, when it is halted, or when it is restarting because of system problems.
The following table describes other error messages that might appear on the system console if your appliance encounters errors while starting up or during operation.
If the system stops on one of these error codes, there is likely a hardware problem. First, try Step 1 below. If this doesn't fix the problem, proceed to the subsequent steps until the problem is fixed.
|
||
Running on CPU0, on memory segment 0 (that is, program is now running in RAM rather than flash memory). |
If the system stops on this error code, the memory is bad or the NVLOG subsystem malfunctioned. To test this, reseat the DIMM and disconnect the battery. See Replacing FAS250 Devices. If that fails to clear the problem, replace the DIMM. See Replacing the SDRAM DIMM on the CPU module. |
|
Check the connection between your appliance and the console device. Replace the cable if it is defective. |
||
A message of this type doesn't indicate a specific failure, but a general failure of some system component.
|
||
If the system stops with one of these error codes, there is likely a problem with either the SB1250 or the ISP2312 FC-AL chip.
|
||
This message is written when CFE jumps to the exception handler, for whatever reason. This is caused by either bad hardware or a bad flash memory. |
|