Hot upgrading a DS14 disk shelf and hot swapping LRC/ESHs
Tasks for hot upgrading and hot swapping
This section contains information about hot upgrading a DS14/DS14mk2 FC disk shelf to a cluster and how to hot swap an LRC/ESH module in a cluster. It describes the procedures in the following sections:
Requirements for upgrading and hot swapping
Upgrading a cluster that contains DS14/DS14mk2 FC disk shelves with LRC modules to a cluster containing DS14/DS14mk2 FC disk shelves with ESH modules requires that you exchange the LRC modules with ESH modules.
Hot upgrading your DS14 disk shelves
To convert your DS14/DS14mk2 FC disk shelves with LRCs into disk shelves with ESH modules, complete the following steps.
Step
|
Action
|
|
1 |
If the cluster is a...
|
Then...
|
Standard cluster, mirrored cluster, non-switched MetroCluster, or switched MetroCluster
|
- Take over the partner filer's
disk shelves by entering the
following command on the
local filer:
cf takeover
- Go to Step 2.
|
Fabric Attached MetroCluster
|
Go to Step 2.
|
|
2 |
Note the terminator switch position of the LRC you are replacing. The new ESH module must be set to the same setting as the old LRC.
|
|
3 |
While grounded, unplug the cabling from the partner filer's disk shelves. Note the cable locations, especially if your cluster is a Fiber Attached MetroCluster.
|
|
4 |
Remove the Channel A loop LRCs of the partner's disk shelves and replace them with ESH modules.
|
|
5 |
Recable the disk shelves to their original locations before the ESH installation.
|
|
6 |
Check the operation of the new ESH modules by entering the following command from the local node console:
environ shelf
Result
The local filer reports the status of the modified shelves as good.
|
|
7 |
If clustering was...
|
Then...
|
Disabled
|
- Return control of the partner
filer's disk shelves by
entering the following
command:
cf giveback
- Repeat Steps 2 through 6 for
the Channel B loop.
|
Not disabled
|
Repeat Steps 2 through 6 for the Channel B loop.
|
|
8 |
Repeat Steps 1 through 7 for the local filer.
|
|
9 |
Test the configuration as described in Chapter 1, Step 5: Completing setup and testing your cluster.
|
Hot swapping a single LRC/ESH module
To hot swap a single LRC/ESH module, complete the following steps.
Step
|
Action
|
|
1 |
Take over the partner filer's disk shelves by entering the following command on the local filer:
cf takeover
|
|
2 |
Note the terminator switch position of the LRC or terminator and loop speed switches of the ESH you are replacing. The new LRC/ESH module must be set to the same settings as the old LRC/ESH.
|
|
3 |
While grounded, unplug the cabling from the target LRC/ESH module, then remove the module.
|
|
4 |
Slide the replacement LRC/ESH module into the slot at the rear of the disk shelf and push the levers of the CAM mechanism into place.
|
|
5 |
Reconnect the cabling to the replacement LRC/ESH.
|
|
6 |
Return control of the partner filer's disk shelves by entering the following command:
cf giveback
|
Testing the LRC/ESH modules
To test your LRC/ESH modules, complete the following steps on both nodes.
Step
|
Action
|
|
1 |
Verify that all disk shelves with ESH modules are functioning properly by entering the following command:
environ shelf
Results
The system reports the modules as good.
|
|
2 |
Verify that you can create and retrieve files on both nodes for each licensed protocol.
|
|
3 |
Verify there are no missing disks by entering the following command:
vol status -r
Result
Local disks displayed on the local node should be displayed as partner disks on the partner node and vice-versa.
|
Troubleshooting takeover or giveback failures
If takeover or giveback fails, complete the following steps.
Step
|
Action
|
|
1 |
Check the Channel B cabling on the disk shelves, and tighten any lose cables.
|
|
2 |
Check the cabling to the cluster interconnect adapter. Make sure that the cables are connected to the correct interconnect adapter ports and that they are secure.
|
|
3 |
Check communication between the nodes by entering the following command:
cf status
Result
If there is a cabling error or the interconnect link is down, the system displays an error message indicating the error.
|
|
4 |
Check the parameters and option settings on your cluster with the cluster configuration checker script.
This script is available for download from the NOW Web site at http://now.netapp.com/NOW/tools. Look for the cluster configuration checker (cf-config-check.cgi) file.
|
|
5 |
Check network connectivity.
See the appropriate System Administration guide for more information.
|
|
6 |
Reboot the cluster and rerun the takeover and giveback tests.
|
Copyright © 1994-2003, Network Appliance, Inc. All rights
reserved.
Part No. 210-00341
File: ch4dsk7.htm
Last updated: 05/01/03 17:39:36