You must have the following equipment for a MetroCluster. See the System Configuration Guide to confirm that this information is current.
Required equipment
|
MetroCluster
|
MetroCluster with QuickLoop
|
Fabric Attached MetroCluster
|
Distance between nodes
|
30 to 500 meters
|
500 meters to 10 kilometers
|
500 meters to 30 kilometers
|
Appliance type for nodes
|
Two of the same type of any F800 series appliance
|
Two F880 or two F825 appliances
|
Storage
|
Up to the maximum for mirrored clusters. See the System Configuration Guide for storage maximums.
|
Four or eight TB of storage of DS14 disk shelves in the cluster. The DS14 disk shelves must have optical LRCs.
|
Up to 32 TB of storage for DS14 and DS14mk2 FC disk shelves.
|
Cluster adapter supported
|
IB cluster adapter
VI cluster adapter, Rev. B
|
VI cluster adapter, Rev. B
|
VI-MC cluster adapter
|
FC HBA (FC HBA for Disk) adapters
|
None
|
Two per node
The ports on the FC HBA adapters are labeled 1 and 2. However, the software refers to them as a and b. You see these labeling conventions in the user interface and system messages displayed on the console.
|
Switches
|
None
|
Two 16-port, Brocade 3800 switches or two 8-port Brocade 3200 switches.
|
Four 16-port, Brocade 3800 switches, or Four 8-port Brocade 3200 switches, or two Brocade 3800 switches on one side of the cluster and two Brocade 3200 switches on the other side of the cluster.
|
SFP modules
|
None
|
Two per ISL, long distance
One per switch port used, short distance
|
Two per ISL, long distance
One per switch port used, short distance
|
Cables
|
- Four SC/LC FC-AL to disk shelf cables
- Two SC/LC VI cluster adapter-to-switch cables
- Four SC/LC disk shelf-to-switch cables
|
- Four SC/LC FC-AL to disk shelf cables
- Two SC/LC VI cluster adapter-to-switch cables
- Four SC/LC disk shelf-to-switch cables
- Four LC/LC node-to-switch cables
- Two LC/LC ISL (Inter Switch Links) cables, not provided in shipment
|
- LC/LC node-to-switch cables
- SC/LC (for DS14) or LC/LC (for DS14mk2 FC) disk shelf-to-switch cables
- Two LC/LC ISL cables, not provided in shipment
- HSSDC2-to-HSSDC2 for DS14 disk shelves with ESH modules or DB-9 to DB-9 shelf-to-shelf cabled
|
You must have the following software, firmware, and licenses for a MetroCluster or Fabric Attached MetroCluster:
The following list specifies the manuals you should have available when installing a MetroCluster: