To convert an existing cluster into a Fabric Attached MetroCluster, complete the following steps.
| 1 |
Update Data ONTAP, appliance firmware, and disk firmware, as described in the Data ONTAP Upgrade Guide, making sure to shut down the nodes to the OK prompt. |
|
| 2 |
Update your hardware by replacing components, as described in Failed adapters. Note |
|
| 3 |
Determine your switch and cluster configuration by completing the planning worksheet in Step 1: Planning the Fabric Attached MetroCluster. |
|
| 4 |
Set up and configure the local switches, as described in Step 2: Configuring the local switches. |
|
| 5 |
Cable the local node, as described in Step 3: Cabling the local node. |
|
| 6 | ||
|
Set up mirroring and configure the local node, as described in Step 3: Cabling the local node. | ||
|
Proceed to Step 7. | ||
| 7 |
Transport the partner node, disk shelves, and switches to the remote location. |
|
| 8 |
Set up the remote node, disk shelves, and switch, as described in Step 4: Cabling the switches and nodes at the partner site. |
|
| 9 |
Configure the cluster, as described in Step 5: Configuring the nodes. |
|
Copyright © 1994-2004, Network Appliance, Inc. All rights
reserved.
Part No. 210-00651
File: ch3metr9.htm
Last updated: 04/05/04 17:01:03