Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments

Converting a cluster into a Fabric Attached MetroCluster

Converting a cluster  Top

To convert an existing cluster into a Fabric Attached MetroCluster, complete the following steps.

Step

Action

1

Update Data ONTAP, appliance firmware, and disk firmware, as described in the Data ONTAP Upgrade Guide, making sure to shut down the nodes to the OK prompt.

2

Update your hardware by replacing components, as described in Failed adapters.

Note
You must have FC HBA for Disk adapters installed in each node, and each node must have VI-MC cluster adapters.

3

Determine your switch and cluster configuration by completing the planning worksheet in Step 1: Planning the Fabric Attached MetroCluster.

4

Set up and configure the local switches, as described in Step 2: Configuring the local switches.

5

Cable the local node, as described in Step 3: Cabling the local node.

6

If you are converting a...

Then...

Standard cluster

Set up mirroring and configure the local node, as described in Step 3: Cabling the local node.

Nonswitched MetroCluster

Proceed to Step 7.

7

Transport the partner node, disk shelves, and switches to the remote location.

8

Set up the remote node, disk shelves, and switch, as described in Step 4: Cabling the switches and nodes at the partner site.

9

Configure the cluster, as described in Step 5: Configuring the nodes.

Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments