The procedure for correcting a takeover or giveback failure on an F800 series cluster is different from that of a FAS900 series cluster. See one of the following sections according to your system hardware:
If takeover or giveback fails on an F800 series cluster, complete the following steps.
The following table describes tests you can run to determine why takeover or giveback failed and also provides information to correct the problem.
Note
You must reboot the cluster after completing each test.
To correct a takeover or giveback failure, complete the following steps.
| 1 |
Check communication between the local and partner nodes by entering the following command and observing the messages: cf status ResultIf there is a problem with cabling or the adapter, the appropriate message is displayed. Recable or replace the cluster adapter, as needed. |
|
| 2 | ||
|
Check the cluster adapter cabling. Make sure that the cabling is correct and properly seated at both ends of the cable. | ||
|
Check the NVRAM5 slot number. Move it to the correct slot if it is in the wrong one. | ||
|
Check the cabling of the Channel B disk shelf loops and reseat and tighten any loose cables. | ||
| 3 |
Run the cluster configuration checker script, as described in Setting options and parameters with the cluster configuration checker. |
|
| 4 |
Reboot the cluster and rerun the takeover and giveback tests. |
|
| 5 |
If you still do not have clustering enabled, call Customer Support. |
|