Upgrading LRC modules to ESH or ESH2 modules

Reasons for upgrading an LRC  Top

If your cluster has disk shelves that have LRC modules and you add a DS14/DS14mk2 FC disk shelf that has ESH/ESH2 modules, you need to replace the LRC modules with ESH/ESH2 modules in the existing DS14 disk shelves.

This section describes how to upgrade your LRC modules to ESH/ESH2 modules. It also describes how to hot-swap a failed LRC or ESH/ESH2 module.

Upgrading a LRC module to an ESH/ESH2 module  Top

To upgrade your DS14/DS14mk2 FC disk shelves with LRC modules into disk shelves with ESH/ESH2 modules, complete the following steps.

Step

Action

1

If the cluster is a...

Then...

Standard cluster, mirrored cluster, nonswitched MetroCluster, or switched MetroCluster

  1. Take over the partner appliance's disk shelves by entering the following command on the local appliance:

    cf takeover

  2. Go to Step 2.

Fabric Attached MetroCluster

Go to Step 2.

2

Note the terminate switch position of the LRC you are replacing. The new ESH module must be set to the same setting as the old LRC.

Note
ESH2 is self-terminating and does not have a termination switch.

3

While grounded, unplug the cabling from the partner appliance's disk shelves. Note the cable locations, especially if your cluster is a Fabric Attached MetroCluster.

4

Remove the Channel A loop LRCs of the partner's disk shelves and replace them with ESH/ESH2 modules.

5

Recable the disk shelves to their original locations before the ESH/ESH2 installation.

6

Check the operation of the new ESH/ESH2 modules by entering the following command from the local node console:

environ shelf

Result

The local appliance reports the status of the modified shelves as good.

7

If a cluster takeover...

Then...

Was performed in Step 1

  1. Return control of the partner appliance's disk shelves by entering the following command:

    cf giveback

  2. Repeat Step 2 through Step 6 for the Channel B loop.

Was not performed in Step 1

Repeat Step 2 through Step 6 for the Channel B loop.

8

Repeat Step 1 through Step 7 to add storage to the partner appliance.

9

Test the configuration, as described in Step 5: Checking and testing cluster configuration.