The assumptions about this procedure are that the LRC, ESH, and ESH2 modules on the disk shelf are multipath connections to the appliance and that you are hot-swapping an LRC with another LRC, an ESH with another ESH, an ESH2 with another ESH2, or an ESH with an ESH2.
Note
A hot-swap of an ESH with an ESH2 requires that you upgrade to Data ONTAP 6.4.4 or later and replace both ESH modules in the disk shelf.
Caution
If you attempt to hot-swap the LRC, ESH, or ESH2 module on a disk shelf that does not have multipath connections, you lose all access to the drives on this disk shelf as well as others in the same disk pool.
You can hot-swap an LRC or ESH module in a cluster. To hot-swap a single LRC or ESH module that belongs to the partner node, complete the following steps.
| 1 |
From the console of the appliance, enter the following command to disable the loop in which the failed module is a connection: cf takeover Note |
|
| 2 |
Verify that your appliance meets the minimum software requirements to support the disk shelf modules that you are hot-swapping. See the DiskShelf14 and DiskShelf14mk2 FC Hardware Guide for more information. |
|
| 3 | ||
| 4 | ||
|
Note the position of the terminate switch on the LRC, ESH, or ESH2 you are removing and set the terminate switch on the replacement LRC, ESH, or ESH2 to the same setting before inserting it into the disk shelf. | ||
|
An ESH with an ESH2 for a disk shelf that is either the first shelf in the loop or a shelf in the middle of the loop where all other disk shelves have ESHs | ||
|
An ESH with an ESH2 for a disk shelf that is the last shelf in the loop, where all other disk shelves have ESHs |
On all but the last disk shelf in the loop, place the terminate switch to the Off position on ESH A (up). | |
|
Go to Step 5. | ||
| 5 | ||
|
Disconnect the module that you are removing from the Fibre Channel cabling. | ||
|
Disconnect the ESH from the Fibre Channel cabling and remove the cabling. | ||
| 6 |
Using the thumb and index finger of both hands, press the levers on the CAM mechanism on the module to release it and pull it out of the disk shelf. |
|
| 7 |
Slide the replacement module into the slot at the rear of the disk shelf and push the levers of the CAM mechanism into place. Caution |
|
| 8 | ||
|
An ESH with an ESH2 if it is the first shelf in the loop where all other disk shelves have ESHs | ||
|
An LRC, ESH, or ESH2 if it is a shelf in the middle of the loop, or the last shelf in the loop, where all other disk shelves have ESHs |
Use HSSDC2-to-SFP cables for connections between a disk shelf with ESH and a disk shelf with ESH2. | |
| 9 |
From the console of the appliance, enter the following command to enable the loop in which the replacement module is a connection: cf giveback |
|
| 10 | ||
| 11 |
Test the replacement module, as described in Testing the modules." |
|
To test your LRC, ESH, or ESH2 modules, complete the following steps on both nodes.
Copyright © 1994-2004, Network Appliance, Inc. All rights
reserved.
Part No. 210-00651
File: ch5_trb8.htm
Last updated: 04/05/04 17:01:07