Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments

Operational error messages

When operational error messages appear  Top

These error messages might appear on the system console or LCD when the system is operating, when it is halted, or when it is restarting because of system problems.

General error messages  Top

The following table describes other error messages that might appear on the LCD if your storage engine encounters errors while starting up or during operation.

Error message

Explanation

Fatal?

Corrective action

Disk n is broken

n--The RAID group disk number. The solution depends on whether you have a hot spare in the system.

No

See the System Administration Guide for information about how to locate a disk based on the RAID group disk number and how to replace a faulty disk.

Fans stopped; replace them

One of the fan subassemblies of your storage engine failed.

No

Replace the failed fan subassembly as soon as possible.

Power supply degraded

One of the power supply units is turned off, was removed from your storage engine, or failed.

No

Verify that both power supplies are installed and turned on. If you still get this error, replace the power supplies one at a time to determine the failed power supply.

Dumping core

The system is dumping core after a system crash.

Yes

Write down the system crash message on the system console and report the problem to Network Appliance Customer Support.

Disk hung during swap

A disk error occurred as you were hot swapping a disk.

Yes

  1. Disconnect the disk from the power supply by opening the latch and pulling it half-way out.
  2. Wait 15 seconds to allow all disks to spin down.
  3. Reinstall the disk.
  4. Restart the system by entering the following command:
    boot
    

Error dumping core

The system cannot dump core during a system crash and restarts without dumping core.

Yes

Report the problem to Network Appliance Customer Support.

Panicking

The system is crashing. If the system does not hang while crashing, the message Dumping core appears.

Yes

Report the problem to Network Appliance Customer Support.

System too hot

The temperature sensor indicates that the system temperature is too high.

Yes

Verify that the ventilation holes on the top cover of the system are not blocked. If the ventilation holes are not blocked and the problem persists, contact Network Appliance Customer Support for help.

AT-FC error messages  Top

The following table describes other error messages that might appear on the console if your storage engine encounters AT-FC module errors while starting up or during operation. The output displayed on the console is similar to the following example.

Example

Wed Aug  6 19:31:40 PDT [scsi.cmd.notReadyCondition:notice]: Device 
11b.44: Device returns not yet ready: CDB 0x41:026d0880:5000: Sense 
Data SCSI:not ready -  (0x2 - 0x4 0x7 0x0)(28615).

Sense key

ASC

ASCQ

Description on console

Corrective action

00h
00h
00h
No sense

No action.

01h
5Dh
20h
Recovered error, controller 
impending error, general hard 
drive failure, SMART 
notification.

Notification was sent out and follow-on log messages identify and clarify corrective action.

02h
04h
00h
Not ready, cause not reportable 
(drive failed to spin-up and 
become ready).

No action.

02h
04h
01h
Not ready, logical unit is in 
the process of becoming ready 
(drive spinning up).
02h
04h
 03h
Logical unit not ready, manual 
intervention required (drive 
failed to become ready after 
error recovery or drive not 
installed).

Replace or install a disk drive in the identified location, as described in Replacing a disk in a disk shelf.

02h
04h
07h
Logical unit not ready, command 
in progress (drive command 
timeout).

No action.

03h
11h
00h
Media error, unrecoverable read 
error (ATA UNC).
03h
12h
00h
Media error, address mark not 
found for ID (ATA AMNF, drive 
vendor unique)
03h
14h
01h
Medium error, record not found. 
(ATA IDNF)
03h
15h
01h
Medium error, mechanical 
positioning error (ATA TRK0 NF, 
drive vendor unique).

No action.

04h
44h
00h
Hardware error, internal target 
failure (ATA FW PROB, drive 
vendor unique or unrecognized 
ATA error).
05h
20h
00h
Illegal request, invalid command 
Op Code.
05h
21h
00h
Illegal request, logical block 
address out of range.
05h
24h
00h
Illegal request, invalid field 
in CDB.
05h
26h
00h
Illegal request, invalid field 
in parameter list.
06h
29h
00h
Unit attention, reset or target 
reset occurred.
06h
29h
01h
Unit attention, power-on 
occurred.
06h
3Fh
03h
Unit attention, inquiry data 
changed.
0Bh
08h
03h
Hardware error, logical unit 
communication error (ATA ICRC).

Check the connections to ensure that they are secure and tight. If the error persists, change the cables.

0Bh
44h
00h
Aborted command, internal target 
failure (ATA ABRT).

No action.

Additional AT-FC error messages  Top

The following error messages appear on the storage appliance console if an SES element on the AT-FC module fails. See Replacing the AT-FC module for more information. The output displayed on the console is similar to the following example.

Example

Mon Aug 25 21:34:05 GMT [ses.status.temperatureWarning:warning]: 
DS14-Mk2-AT shelf 3 on channel 5a temperature warning for 
Temperature sensor 1: non-critical status; undertemperature 
warning. Current temperature: 1 C (33 F). This module is on the 
front side of the shelf, at the right, on the OPS panel.

Error message

Corrective action

Temperature sensor 2: failed

Contact Network Appliance Customer Support.

Temperature sensor 3: failed
SES electronics Element 1: 
component is from a different 
product family

This configuration is unsupported. Contact Network Appliance Customer Support.

SES electronics Element 1: failed

Contact Network Appliance Customer Support.

SES electronics Element 2: failed

The AT-FC module on the disk shelf failed. Replace the AT-FC module, as described in Replacing the AT-FC module.

Temperature sensor 2: not installed 
or failed

Contact Network Appliance Customer Support.

Environmental sensor 3: not 
installed or failed

Contact Network Appliance Customer Support.

SES electronics Element 1: not 
installed or failed
Vendor-specific Element 1: not 
installed or failed
SES electronics Element 2: not 
installed or failed

Communication with the temperature sensor on the AT-FC module failed. Replace the AT-FC module, as described in Replacing the AT-FC module.

Vendor-specific Element 2: not 
installed or failed

Disk shelf error messages  Top

The following table lists the disk shelf error messages from the front panel and the power supplies, that might be displayed on the console if you encounter disk shelf errors during start or operation.

Error message

Corrective action

Front panel messages

Temperature sensor 1: failed

The temperature sensor on the front operation panel failed. Replace the disk shelf, as described in Replacing a disk shelf in a rack.

Alarm Element 1: failed

The alarm on the front operation panel failed. Replace the disk shelf, as described in Replacing a disk shelf in a rack.

Display Element 1: failed 

The display element on the front operation panel failed. Replace the disk shelves, as described in Replacing a disk shelf in a rack.

Power supply messages

Power supply 1: failed

The power supply on the left back of the disk shelf failed. Replace the power supply, as described in Replacing a power supply in a disk shelf.

Power supply 2: failed

The power supply on the right back of the disk shelf failed. Replace the power supply, as described in Replacing a power supply in a disk shelf.

Cooling element Element 1: failed

The fan module on the left back power supply failed. Replace the power supply, as described in Replacing a power supply in a disk shelf.

Cooling element Element 2: failed

The fan module on the right back power supply failed. Replace the power supply, as described in Replacing a power supply in a disk shelf.

Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments