environment status
environment [ status ] shelf
environment [ status ] chassis
[ all | <class> | <class> | ... | <class> ]
where class is a set of jointly monitored chassis sensors, e.g., all the motherboard's temperature sensors, or just one CPU fan sensor.
Usage: environment status |
[status] [shelf []] |
[status] [chassis [all | Fans | CPU_Fans | Power | Temperature | PS1 | PS2]]
Environment for adapter 3:
Shelves monitored: 1 enabled: yes
Swap in progress? no Environmental failure? no
EDM 1 (active):
SES Configuration, via loop id 3 in shelf 0x0:
logical identifier=0x3003040000000000
vendor identification=EuroLogc
product identification=Eurologic EDM
product revision level=0x01000101
Vendor-specific information:
backplane byte=0x1e cabinet id=0x0
Backplane Type : Single Fibre Channel Backplane
Backplane Function : Storage System
Kernel Version : 1.0.A App. Version : 1.1.A
Shelf:0 SES path:3.3 Device mask: 0x7f
Power Supply present: 0x3; with error: 0x0
Fans present: 0x3; with error: 0x0
Temperature Sensor present: 0x1; with error: 0x0
SES Electronics present: 0x1; with error: 0x0
Shelf temperature: 29C (84F)
High thresholds: critical: 55C (131F); warning 50C (122F)
Low thresholds: critical: 0C (32F); warning 10C (50F)
Disks physically present on adapter 3
Devices 0x1f-0x00: 0000007f
Devices 0x3f-0x20: 00000000
Devices 0x5f-0x40: 00000000
Devices 0x7f-0x60: 00000000
Displays all non-shelf environmental information for the filer.
environment chassis [ all | <class> | <class> | ...
|<class> ]
environment status chassis [ all | <class>
<class> | ... |<class> ]
Displays the environmental status for the specified class (see NOTE above).
NOTE: environment [status] chassis will list the available chassis classes that can be viewed specifically.
produces the environmental readings for the shelves attached to adapter 3 as follows:
No shelf environment available from adapter 0a.
Environment for adapter 1:
Shelves monitored: 1 enabled: yes
Swap in progress? no Environmental failure? no
EDM 0 (active):
SES Configuration, via loop id 3 in shelf 0x0:
logical identifier=0x3003040000000000
vendor identification=EuroLogc
product identification=Eurologic EDM
product revision level=0x01000101
Vendor-specific information:
backplane byte=0x1e cabinet id=0x0
Backplane Type : Single Fibre Channel Backplane
Backplane Function : Storage System
Kernel Version : 1.0.A App. Version : 1.1.A
Shelf:0 SES path:1.3 Device mask: 0x7f
Power Supply present: 0x1; with error: 0x0
Fans present: 0x3; with error: 0x0
Temperature Sensor present: 0x1; with error: 0x0
SES Electronics present: 0x1; with error: 0x0
Shelf temperature: 30C (86F)
High thresholds: critical: 55C (131F); warning 50C (122F)
Low thresholds: critical: 0C (32F); warning 10C (50F)
Disks physically present on adapter 1
Devices 0x1f-0x00: 0000007f
Devices 0x3f-0x20: 00000000
Devices 0x5f-0x40: 00000000
Devices 0x7f-0x60: 00000000