To prevent filer panics or double disk failure due to excessive media errors encountered during single-disk failure reconstruction, Data ONTAP tracks media errors on each active filer disk and sends a disk failure request to the RAID system if system-defined media error thresholds are crossed on that disk.
Disk media error thresholds that trigger a disk failure request include
If the filer volume is not already running in degraded mode due to single-disk failure reconstruction when the disk failure request is received, RAID will fail the disk in question, swap in a hot spare disk, and begin RAID reconstruction to replace the failed disk.
Failing disks at the thresholds listed in this section ensures that a disk will be replaced before the number of media errors on that disk increases the likelihood of a filer panic or double-disk failure during a single-disk failure reconstruction.
Copyright © 1994-2003, Network Appliance, Inc. All rights
reserved.
Part No. 210-00472
File: raid19.htm
Last updated: 11/17/03 16:57:27