The following sections discuss upgrade issues that you should be aware of if you are upgrading from releases earlier than Data ONTAP 6.2.
If you are upgrading from a release that has the raid.reconstruct_speed knob, you should be aware that the options and settings for this feature changed in Data ONTAP 6.2. The raid.reconstruct_speed option can still be set, but it only affects the value of raid.reconstruct.perf_impact, which is one of four new options. The ten settings previously used for the raid.reconstruct_speed knob translate to three settings for the new options, as follows:
For more information about the raid.reconstruct_speed option, see the latest Storage Management Guide.
Load-balancing algorithms for virtual interfaces (vifs) were introduced in Data ONTAP 6.2. If you are using vifs, and you upgrade to Data ONTAP 6.2 or later from a pre-6.2 release, the network traffic flow out of the system may change. This could be because the vifs follow the default IP-based load-balancing policy. However, since the default load-balancing policy for most of the switches is IP-based, traffic flow is usually not disturbed. If the outbound flow of the network is not sufficiently balanced, you can change the load-balancing policy on the vif. For more information, see the Network Management Guide.
Copyright © 1994-2004, Network Appliance, Inc. All rights
reserved.
Part No. 210-00913-B0
File: upgrad10.htm
Last updated: 04/20/04 17:27:34