This section provides information about how to hot-add a DS14/DS14mk2 FC to an existing loop. It also tabulates the error messages that appear on your storage appliance console if the attempt at hot-adding was unsuccessful.
Note
The hot-added disk shelf must have new drives that will be used as spares only.
To hot-add a DS14/DS14mk2 FC to an existing loop, the following requirements must be met.
|
|
The disk shelves in the existing loop must have only DS14/DS14mk2 FC disk shelves with ESHs in the loop. |
To hot-add a disk shelf to an existing loop, complete the following steps.
Caution
To hot-add disk shelves to a cluster, see the cluster guide for your filer.
| 1 | ||
| 2 |
Follow Step 2 through Step 7 of Installing a disk shelf. |
|
| 3 |
Ground the disk shelf using the provided grounding cable. Follow Step 4 and Step 5 of Grounding connected disk shelves. |
|
| 4 |
Connect the disk shelf to a power source by following Step 2 of Connecting the disk shelf to power. Caution |
|
| 5 |
Give the disk shelf a unique disk shelf ID. See Step 5 of Installing a disk shelf for specific instructions. Note |
|
| 6 |
Verify that the disk shelf ID is not being used in the loop by entering the following command at the console: fcstat device_map adaptername Caution |
|
| 7 | ||
|
||
| 8 |
Turn on the power to the disk shelf. Caution |
|
| 9 |
Connect one end of the provided cable to the LRC/ESH A Output on the last disk shelf in the existing loop. |
|
| 10 |
Connect the other end of the cable to the LRC/ESH A Input on the new disk shelf. |
|
| 11 |
Connect one end of the provided cable to the LRC/ESH B Output on the last disk shelf in the existing loop. |
|
| 12 |
Connect the other end of the cable to the LRC/ESH B Input on the new disk shelf. |
|
| 13 |
Verify that all the cables are securely fastened. Caution |
|
| 14 |
Turn the termination switch of the newly added disk shelf to the On position for LRC/ESH A (down) and LRC/ESH B (up). Caution |
|
| 15 |
Turn the termination switch of the now second-to-last disk shelf to the Off position for LRC/ESH A (up) and LRC/ESH B (down). ResultIn 60 seconds, the storage appliance recognizes the hot-added disk shelf. |
|
The following error messages appear on your storage appliance console if your attempt at hot-adding the DS14/DS14mk2 FC is unsuccessful.
Copyright © 1994-2003, Network Appliance, Inc. All rights
reserved.
Part No. 210-00592
File: appa3.htm
Last updated: 12/03/03 13:49:02