You can replace a disk in a disk shelf for any reason. However, the most common reason is disk failure. If a disk fails, the storage appliance logs a warning message to the system console indicating which disk on which loop failed.
In addition, a disk shelf with an ESH module identifies any one of the following situations as disk failure:
The following autosupport warning message is then sent:
DISK FAIL!! - Bypassed by ESH
Before you replace a disk in a disk shelf, you must first check the disk shelf to ensure that after you remove the disk you still have enough disks installed to meet the enclosure services requirements. For information about these requirements, see Drive bay requirements.
Replacing a disk in a disk shelf consists of the following procedures:
To remove a disk, complete the following steps.
| 1 | ||
| Filer/FAS appliance |
If you are removing disk that is a member of a volume, enter: disk fail disk_name If you are removing disk that is a spare disk, enter: disk remove disk_name Either command causes the amber fault LED on the disk to illuminate. For more information about LEDs, see Monitoring the Fibre Channel disk. For more information about disk commands, see the Data ONTAP System Administrator's Guide. |
|
For more information about disk management, see the NetCache Appliance System Administration Guide. |
||
| 2 | ||
| 3 |
Put on the antistatic wrist strap and grounding leash. |
|
| 4 |
To remove the disk, press down on its release mechanism with one hand while grasping the top flange of the disk shelf with the other hand. Gently slide the disk out of the disk shelf. WARNING |
|
To install a disk in a disk shelf, complete the following steps.
Copyright © 1994-2003, Network Appliance, Inc. All rights
reserved.
Part No. 210-00592
File: devices5.htm