Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments

Differences between the DS14 and DS14mk2 FC

Differences between the disk shelves  Top

The following table lists the differences between the DS14 and the DS14mk2 FC.

Note
See the System Configuration Guide at http://now.netapp.com for information about the storage appliance supporting the disk shelf configuration.

Features

DS14

DS14mk2 FC

Shelf chassis

Front:

Drive bays are not keyed.

Back:

Power supply bays are not keyed.

Front:

Drive bays are keyed to prevent the use of unsupported drives.

Back:

Power supply bays are keyed to prevent the use of older power supplies that are incompatible.

Existence of a 1-Gb/2-Gb loop-speed switch.

Drives in drive carriers

Drive carriers are unkeyed and cannot be used with DS14mk2 FC.

Drive carriers are keyed and can be used with DS14.

Power supplies

  • Power supplies are unkeyed and cannot be used with DS14mk2 FC.
  • AC and DC power supplies are available.
  • Power supplies are keyed and can be used with DS14.
  • Only AC power supplies are available.

LRC

  • Requires Data ONTAPTM 6.0 software or later
  • Requires NetCache 5.1 or later
  • LRC functions at 1-Gb loop speed
  • Requires Data ONTAP 6.4.1 or later
  • Requires NetCache 5.5 or later
  • LRC functions at 1-Gb loop speed and requires the loop-speed switch to be set at 1-Gb.

ESH

  • Requires Data ONTAP 6.2 or later
  • ESH functions at 1-Gb loop speed.
  • Requires Data ONTAP 6.4.1 or later
  • Requires NetCache 5.5 or later
  • ESH functions at 1-Gb or 2-Gb loop speed, depending on the system needs.

Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments